» Articles » PMID: 15776484

Comparison of Sheathless and Sheath-flow Electrospray Interfaces for the Capillary Electrophoresis-electrospray Ionization-mass Spectrometry Analysis of Peptides

Overview
Journal Electrophoresis
Specialty Chemistry
Date 2005 Mar 19
PMID 15776484
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Capillary electrophoresis coupled to mass spectrometry via an electrospray interface provides a powerful system for separation and characterization of a high number of biomolecules. The present paper describes a home-made sheathless interface and compares it with a commercial sheath-flow interface, using a separation method based on a peptide hormone mixture of therapeutic interest. In a previous work, we optimized the parameters involved in a sheath-flow interface and obtained good results in sensitivity and reproducibility. The sheathless interface is performed with a graphite-coated electrospray ionisation (ESI) tip attached to the separation capillary. We demonstrate that electrolyte composition is the main parameter affecting signal sensitivity and separation resolution. The effect of the nature and concentration of the organic solvent added to the separation electrolyte is carefully studied. Furthermore, a general comparison of both interfaces is made in terms of separation, reproducibility, and sensitivity obtained under the optimized conditions described. Advantages and disadvantages of both coupling setups have been evaluated.

Citing Articles

Capillary Electrophoresis-Mass Spectrometry with Multisegment Injection and In-Capillary Preconcentration for High-Throughput and Sensitive Determination of Therapeutic Decapeptide Triptorelin in Pharmaceutical and Biological Matrices.

Piestansky J, Cizmarova I, Stefanik O, Matuskova M, Horniakova A, Majerova P Biomedicines. 2021; 9(10).

PMID: 34680605 PMC: 8533539. DOI: 10.3390/biomedicines9101488.


Recent Advances and New Perspectives in Capillary Electrophoresis-Mass Spectrometry for Single Cell "Omics".

DeLaney K, Sauer C, Vu N, Li L Molecules. 2018; 24(1).

PMID: 30583525 PMC: 6337428. DOI: 10.3390/molecules24010042.


A stability indicating capillary electrophoresis method for analysis of buserelin.

Tamizi E, Kenndler E, Jouyban A Iran J Pharm Res. 2014; 13(3):797-807.

PMID: 25276180 PMC: 4177640.


A study of electrospray ionization emitters with differing geometries with respect to flow rate and electrospray voltage.

Reschke B, Timperman A J Am Soc Mass Spectrom. 2011; 22(12):2115-24.

PMID: 21989703 DOI: 10.1007/s13361-011-0251-4.


Recent developments in CE and CEC of peptides.

Kasicka V Electrophoresis. 2007; 29(1):179-206.

PMID: 18046694 PMC: 7159161. DOI: 10.1002/elps.200700550.