» Articles » PMID: 15723410

Oxygen-sensitive Contrast in Blood for Steady-state Free Precession Imaging

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2005 Feb 22
PMID 15723410
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Steady-state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal-to-noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals show substantial sensitivity to small off-resonance frequency variations. However, that mechanism cannot explain the oxygen-sensitive contrast in blood that was observed with steady-state methods using phase-cycled radiofrequency pulses. From theoretical and experimental models it is demonstrated that the mechanism responsible for such contrast originates from the motion of spins through local field inhomogeneities in and around deoxygenated red blood cells. In addition, this work shows that it is critical to choose the scan parameters carefully for robust oxygen-sensitive contrast. Finally, it is demonstrated that it is possible to build a quantitative model that incorporates the Luz-Meiboom model, which had been used in the past to estimate quantitative measures of vascular blood oxygen levels. It is envisioned that this method could be instrumental in real-time imaging focused on detecting diseases where the oxygen state of blood is impaired.

Citing Articles

Pure balanced steady-state free precession imaging (pure bSSFP).

Schaper J, Bauman G, Ganter C, Bieri O Magn Reson Med. 2021; 87(4):1886-1893.

PMID: 34775622 PMC: 9299476. DOI: 10.1002/mrm.29086.


From signal-based to comprehensive magnetic resonance imaging.

Kotek G, Nunez-Gonzalez L, Vogel M, Krestin G, Poot D, Hernandez-Tamames J Sci Rep. 2021; 11(1):17216.

PMID: 34446804 PMC: 8390767. DOI: 10.1038/s41598-021-96791-w.


FMRI based on transition-band balanced SSFP in comparison with EPI on a high-performance 0.55 T scanner.

Wang Y, van Gelderen P, de Zwart J, Campbell-Washburn A, Duyn J Magn Reson Med. 2021; 85(6):3196-3210.

PMID: 33480108 PMC: 7904622. DOI: 10.1002/mrm.28657.


Heart Rate-Independent 3D Myocardial Blood Oxygen Level-Dependent MRI at 3.0 T with Simultaneous N-Ammonia PET Validation.

Yang H, Dey D, Sykes J, Butler J, Biernaski H, Kovacs M Radiology. 2020; 295(1):82-93.

PMID: 32096705 PMC: 7106942. DOI: 10.1148/radiol.2020191456.


The impact of vessel size, orientation and intravascular contribution on the neurovascular fingerprint of BOLD bSSFP fMRI.

Baez-Yanez M, Ehses P, Mirkes C, Tsai P, Kleinfeld D, Scheffler K Neuroimage. 2017; 163:13-23.

PMID: 28890417 PMC: 5857886. DOI: 10.1016/j.neuroimage.2017.09.015.