» Articles » PMID: 15653658

Patient-specific Dosimetry in Predicting Renal Toxicity with (90)Y-DOTATOC: Relevance of Kidney Volume and Dose Rate in Finding a Dose-effect Relationship

Overview
Journal J Nucl Med
Specialty Nuclear Medicine
Date 2005 Jan 18
PMID 15653658
Citations 105
Authors
Affiliations
Soon will be listed here.
Abstract

Unlabelled: Nephrotoxicity is the major limiting factor during therapy with the radiolabeled somatostatin analog (90)Y-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA)-d-Phe(1)-Tyr(3)-octreotide (DOTATOC). Pretherapeutic assessment of kidney absorbed dose could help to minimize the risk of renal toxicity. The aim of this study was to evaluate the contribution of patient-specific adjustments to the standard dosimetric models, such as the renal volume and dose rate, for estimating renal absorbed dose during therapy with (90)Y-DOTATOC. In particular, we investigated the correlation between dose estimates and effect on renal function after therapy.

Methods: Eighteen patients with neuroendocrine tumors (9 men and 9 women; median age, 59 y) underwent treatment with (90)Y-DOTATOC (8.1-22.9 GBq) after pretherapeutic biodistribution study with (86)Y-DOTATOC. Kidney uptake and residence times were measured and the absorbed dose (KAD) was computed using either the MIRDOSE3.1 software assuming a standard kidney volume (KAD(StdVol)) or the MIRD Pamphlet 19 values and the actual kidney cortex volume determined by pretherapeutic CT (KAD(CTVol)). For each patient, the biologic effective dose (BED) was calculated according to the linear quadratic model to take into account the effect of dose rate and fractionation. Renal function was evaluated every 6 mo by serum creatinine and creatinine clearance (CLR) during a median follow-up of 35.5 mo (range, 18-65 mo). The individual rate of decline of renal function was expressed as CLR loss per year.

Results: KAD(CTVol) ranged between 19.4 and 39.6 Gy (mean, 28.9 +/- 5.34 Gy). BED, obtained from KAD(CTVol), ranged between 27.7 and 59.3 Gy (mean, 40.4 +/- 10.6 Gy). The CLR loss per year ranged from 0% to 56.4%. In 12 of 18 patients, CLR loss per year was <20%. No correlation was observed between CLR loss per year and the KAD(StdVol) or the KAD(CTVol). In contrast, BED strongly correlated with CLR loss per year (r = 0.93; P < 0.0001). All 5 patients with CLR loss per year >20% received a BED >45 Gy. Patients who were treated with low fractionation were those with the highest rate of renal function impairment.

Conclusion: Radiation nephrotoxicity after (90)Y-DOTATOC therapy is dose dependent. Individual renal volume, dose rate, and fractionation play important roles in an accurate dosimetry estimation that enables prediction of risk of renal function impairment.

Citing Articles

Radioligand therapy in the therapeutic strategy for patients with gastro-entero-pancreatic neuroendocrine tumors: a consensus statement from the Italian Association for Neuroendocrine Tumors (Itanet), Italian Association of Nuclear Medicine (AIMN),....

Panzuto F, Albertelli M, De Rimini M, Rizzo F, Grana C, Cives M J Endocrinol Invest. 2024; 48(1):23-36.

PMID: 39395114 PMC: 11729074. DOI: 10.1007/s40618-024-02448-6.


Pre-clinical evaluation of biomarkers for the early detection of nephrotoxicity following alpha-particle radioligand therapy.

Li M, Robles-Planells C, Liu D, Graves S, Vasquez-Martinez G, Mayoral-Andrade G Eur J Nucl Med Mol Imaging. 2023; 51(5):1395-1408.

PMID: 38095674 PMC: 10957612. DOI: 10.1007/s00259-023-06559-9.


Lesion Dosimetry for [Lu]Lu-PSMA-617 Radiopharmaceutical Therapy Combined with Stereotactic Body Radiotherapy in Patients with Oligometastatic Castration-Sensitive Prostate Cancer.

Grkovski M, ODonoghue J, Imber B, Andl G, Tu C, Lafontaine D J Nucl Med. 2023; 64(11):1779-1787.

PMID: 37652541 PMC: 10626375. DOI: 10.2967/jnumed.123.265763.


Ac-Labeled Somatostatin Analogs in the Management of Neuroendocrine Tumors: From Radiochemistry to Clinic.

Rubira L, Deshayes E, Santoro L, Kotzki P, Fersing C Pharmaceutics. 2023; 15(4).

PMID: 37111537 PMC: 10146019. DOI: 10.3390/pharmaceutics15041051.


Heterogeneity of absorbed dose distribution in kidney tissues and dose-response modelling of nephrotoxicity in radiopharmaceutical therapy with beta-particle emitters: A review.

Vargas C, Andersson M, Bouvier-Capely C, Li W, Madas B, Covens P Z Med Phys. 2023; 34(4):491-509.

PMID: 37031068 PMC: 11624361. DOI: 10.1016/j.zemedi.2023.02.006.