» Articles » PMID: 15629387

Transcatheter Cryoablation of Tachyarrhythmias in Children: Initial Experience from an International Registry

Overview
Date 2005 Jan 5
PMID 15629387
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: We sought to describe the early pediatric experience of transcatheter cryoablation, and identify whether specific arrhythmia substrates and/or ablation locations were particularly suited to cryoablation.

Background: Radiofrequency (RF) ablation has become established therapy for pediatric tachyarrhythmias. However, challenges remain in terms of the safety and efficacy of RF ablation in specific locations; new methods may address these issues.

Methods: Prospective data were available for 64 patients age 13 +/- 4 (mean +/- SD) years undergoing cryoablation at 14 centers participating in the Cryocath International Patient Registry. Dysrhythmia duration was 5.0 +/- 4.2 years, with diagnoses of atrioventricular node re-entrant tachycardia (AVNRT) (n=30), anteroseptal (n=11), midseptal (n=5), or other (n=15) accessory pathway (AP) mediated AV re-entry, ventricular tachycardia (VT) (n = 3), and ectopic atrial tachycardia (EAT) (n=2). Two patients had more than one arrhythmia substrate. Transcatheter cryoablation was offered by cardiologist preference after written informed procedural consent of each patient and/or legal guardian. Cryomapping was performed at -30 degrees C and cryoablation was delivered with 4-min applications at -75 degrees C.

Results: Acute success was achieved in 45 of 65 (69%) cryoablation patients, with best success rates in AVNRT (83%) and right septal AP (75%), and lower success rates in other AP (43%), VT (66%), and EAT (0%). No device-related adverse events were reported. The success of radiofrequency (RF) ablation applied in 14 cryoablation failures was 4 of 4 for AVNRT patients, 1 of 1 for anteroseptal AP patients, 5 of 6 for other AP patients, 0 of 1 for VT patients, and 0 of 2 for EAT patients.

Conclusions: Transcatheter cryoablation is a safe and well-tolerated alternative to RF ablation in pediatric patients on the basis of our initial experience. Success is highest in AVNRT and in substrates recognized as technically challenging or risky for RF ablation.

Citing Articles

Safety and feasibility of 3D-electroanatomical mapping-guided zero or near-zero fluoroscopy catheter ablation for pediatric arrhythmias: Meta-analysis.

Jagannatha G, Antara I, Kosasih A, Adrian J, Mendel B, Labi N J Arrhythm. 2024; 40(4):913-934.

PMID: 39139902 PMC: 11317687. DOI: 10.1002/joa3.13062.


Advancing the science of management of arrhythmic disease in children and adult congenital heart disease patients within the last 25 years.

Paul T, Krause U, Sanatani S, Etheridge S Europace. 2023; 25(8).

PMID: 37622573 PMC: 10450816. DOI: 10.1093/europace/euad155.


A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism.

Pang Y, Chen Q, Xu Y, Cheng K, Ling Y, Ge J J Interv Card Electrophysiol. 2022; 66(2):427-433.

PMID: 35974118 PMC: 9977842. DOI: 10.1007/s10840-022-01343-5.


Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population.

Gulletta S, Vergara P, Gigli L, DAngelo G, Radinovic A, Melania Barbaro C Pediatr Cardiol. 2019; 40(4):713-718.

PMID: 30666358 DOI: 10.1007/s00246-019-02051-0.


Efficacy and safety of cryoablation of para-Hisian and mid-septal accessory pathways using a specific protocol: single-center experience in consecutive patients.

Marazzato J, Fonte G, Marazzi R, Doni L, Mitacchione G, Vilotta M J Interv Card Electrophysiol. 2019; 55(1):47-54.

PMID: 30603856 DOI: 10.1007/s10840-018-0498-9.