» Articles » PMID: 15625259

Needle Placement and Injection Posterior to the Axillary Artery May Predict Successful Infraclavicular Brachial Plexus Block: a Report of Three Cases

Overview
Journal Can J Anaesth
Specialty Anesthesiology
Date 2004 Dec 31
PMID 15625259
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The combined use of ultrasound and nerve stimulation for localization of the brachial plexus during infraclavicular block has not been evaluated. We describe three cases of infraclavicular block where we used ultrasound to place the needle and catheter, observe type of muscle twitch obtained and local anesthetic spread after injection.

Clinical Features: Injection of local anesthetic after obtaining proximal muscle stimulation was associated with local anesthetic spread between the axillary artery and pectoral muscle. This resulted in block failure (case 1). In case 2, proximal stimulation was associated with anterior spread after a test injection. The needle and subsequently the catheter were repositioned posterior to the axillary artery and distal muscle stimulation obtained. Injection through the catheter resulted in local anesthetic spread posterior to the artery and successful block. In case 3, no distal twitch could be obtained but in light of previous experience the needle and then the catheter were placed posterior to the axillary artery. Posterior local anesthetic spread was observed and successful block ensued despite absence of any muscle stimulation.

Conclusion: Ultrasound guidance during infraclavicular brachial plexus block enables direct visualization of needle/catheter tip location and confirmation of appropriate local anesthetic spread. Our early experience suggests that spread of injectate posterior to the second part of the axillary artery is associated with successful block.

Citing Articles

Ultrasound-guided Parasagittal Infraclavicular Block for Patients without Neurostimulation Endpoints: A Case Report in Crush Injuries of the Upper Limb.

Diwan S, Dongre H, Bhong G, Sancheti P J Med Ultrasound. 2024; 32(2):183-185.

PMID: 38882608 PMC: 11175369. DOI: 10.4103/jmu.jmu_92_22.


Ultrasound-guided single needle tip placement below axillary artery in the infraclavicular area: A cadaveric study.

Diwan S, Feigl G, Nair A J Anaesthesiol Clin Pharmacol. 2023; 38(4):658-661.

PMID: 36778830 PMC: 9912874. DOI: 10.4103/joacp.JOACP_694_20.


Use of a curved needle to facilitate lateral sagittal infraclavicular block performance: a randomized clinical trial.

Tammam T, Kamhawy G J Anesth. 2019; 33(5):604-611.

PMID: 31468177 DOI: 10.1007/s00540-019-02674-w.


Comparison of ultrasound-guided axillary brachial plexus block techniques: perineural injection versus single or double perivascular infiltration.

Cho S, Kim Y, Baik H, Kim J, Woo J Yonsei Med J. 2015; 56(3):838-44.

PMID: 25837194 PMC: 4397458. DOI: 10.3349/ymj.2015.56.3.838.


Double-injection perivascular ultrasound-guided axillary brachial plexus block according to needle positioning: 12 versus 6 o'clock position of the axillary artery.

Cho S, Kim Y, Kim J, Baik H Korean J Anesthesiol. 2014; 66(2):112-9.

PMID: 24624268 PMC: 3948437. DOI: 10.4097/kjae.2014.66.2.112.