» Articles » PMID: 15562445

Coupling of Fully Automated Chip Electrospray to Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for High-performance Glycoscreening and Sequencing

Overview
Specialty Chemistry
Date 2004 Nov 25
PMID 15562445
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The NanoMate robot has been coupled to a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer at 9.4 T and implemented for the first time for complex carbohydrate analysis. It was optimized in the negative ion mode to achieve automated sample delivery on the chip along with increased sensitivity, ultra-high resolution and accurate mass determination. A novel bracket has been designed to allow a reliable mounting of the NanoMate to the Apollo electrospray ionization (ESI) source of an APEX II instrument. The notably higher efficiency of ionization for compositional mapping of complex mixtures and feasibility for fragmentation analysis of components by sustained off-resonance irradiation collision-induced tandem mass spectrometry (SORI-CID MS2) has been demonstrated on a glycoconjugate mixture containing O-glycosylated sialylated peptides from urine of a patient suffering from a hereditary N-acetylhexosaminidase deficiency (Schindler's disease), previously analyzed by capillary-based nanoESI-FTICRMS, and of a healthy control person. Due to its potential to generate highly charged ionic species, reduce the in-source fragmentation, increase sensitivity, reproducibility and ionization efficiency, along with the ability to generate a sustained and constant electrospray, this method can be considered as a new platform for advanced glycomics.

Citing Articles

Foodomics and Food Safety: Where We Are.

Andjelkovic U, Srajer Gajdosik M, Gaso-Sokac D, Martinovic T, Josic D Food Technol Biotechnol. 2017; 55(3):290-307.

PMID: 29089845 PMC: 5654429. DOI: 10.17113/ftb.55.03.17.5044.


Recent advances in the MS analysis of glycoproteins: Capillary and microfluidic workflows.

Cortes D, Kabulski J, Lazar A, Lazar I Electrophoresis. 2010; 32(1):14-29.

PMID: 21171110 PMC: 3717299. DOI: 10.1002/elps.201000394.


Development of a high-throughput IMS-IMS-MS approach for analyzing mixtures of biomolecules.

Kurulugama R, Valentine S, Sowell R, Clemmer D J Proteomics. 2008; 71(3):318-31.

PMID: 18590839 PMC: 2626180. DOI: 10.1016/j.jprot.2008.06.010.


Towards liquid chromatography time-scale peptide sequencing and characterization of post-translational modifications in the negative-ion mode using electron detachment dissociation tandem mass spectrometry.

Kjeldsen F, Horning O, Jensen S, Giessing A, Jensen O J Am Soc Mass Spectrom. 2008; 19(8):1156-62.

PMID: 18555696 DOI: 10.1016/j.jasms.2008.04.031.


Response normalized liquid chromatography nanospray ionization mass spectrometry.

Ramanathan R, Zhong R, Blumenkrantz N, Chowdhury S, Alton K J Am Soc Mass Spectrom. 2007; 18(10):1891-9.

PMID: 17766144 DOI: 10.1016/j.jasms.2007.07.022.