» Articles » PMID: 15542212

A Comparative Analysis of the Biomechanical Behaviour of Five Flexor Tendon Core Sutures

Overview
Journal J Hand Surg Br
Date 2004 Nov 16
PMID 15542212
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Five core suture techniques were compared by static tensile testing in vitro. Fifty porcine tendons were used. The core sutures were performed with 3-0 or 4-0 braided polyester suture (Ticron) and the over-and-over running peripheral sutures with 6-0 monofilament polypropylene (Prolene). The core sutures were: (1) Pennington modified Kessler (3-0), (2) Double Pennington modified Kessler (3-0), (3) 4-strand Savage (3-0), (4) 4-strand Savage (4-0), and (5) 6-strand Savage (4-0). Repairs were compared as paired in regard to one variable: the number of core suture strands, the suture calibre, or the suture configuration. Biomechanical differences between the repair groups started during the linear region, with the yield force and stiffness increasing along with the number of core suture strands. All three variables influenced the strain at the yield point. Thus, the strength of the intact repair can be improved by modifying the core suture. In all repairs gap formation started near the yield point after failure of the peripheral suture. The yield force represents the strength of the intact repair composite and should be considered the strength of the tendon repair.

Citing Articles

A retrospective analysis of controlled active motion (CAM) versus modified Kleinert/Duran (modKD) rehabilitation protocol in flexor tendon repair (zones I and II) in a single center.

Wirtz C, Leclere F, Oberfeld E, Unglaub F, Vogelin E Arch Orthop Trauma Surg. 2022; 143(2):1133-1141.

PMID: 35974203 PMC: 9925601. DOI: 10.1007/s00402-022-04506-1.


Polymer-Based Constructs for Flexor Tendon Repair: A Review.

Brebels J, Mignon A Polymers (Basel). 2022; 14(5).

PMID: 35267690 PMC: 8912457. DOI: 10.3390/polym14050867.


Comparison of 4 Different 4-Strand Core Suturing Techniques for Flexor Tendon Laceration: An Ex Vivo Biomechanical Study.

Nassar M, Sallam A, Sokkar S, Abdelsadek H, Zada M Hand (N Y). 2022; 18(5):820-828.

PMID: 35132896 PMC: 10336818. DOI: 10.1177/15589447211073831.


In Vitro Biomechanical Study on the "Figure-of-Eight" and Kessler Sutures in Swine Flexor Tendons.

Kawachi D, Deienno F, Varanda D, Cortopassi A, Sardenberg T Rev Bras Ortop (Sao Paulo). 2020; 55(4):445-447.

PMID: 32904827 PMC: 7458735. DOI: 10.1055/s-0039-1700828.


Repair of flexor tendon injuries by four strands cruciate technique versus two strands kessler technique.

Dawood A J Clin Orthop Trauma. 2020; 11(4):646-649.

PMID: 32684704 PMC: 7355087. DOI: 10.1016/j.jcot.2020.05.038.