Microvolt T-wave Alternans Distinguishes Between Patients Likely and Patients Not Likely to Benefit from Implanted Cardiac Defibrillator Therapy: a Solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II Conundrum

Abstract

Background: In 2003, the Centers for Medicaid and Medicare Services recommended QRS duration as a means to identify MADIT II-like patients suitable for implanted cardiac defibrillator (ICD) therapy. We compared the ability of microvolt T-wave alternans and QRS duration to identify groups at high and low risk of dying among heart failure patients who met MADIT II criteria for ICD prophylaxis.

Methods And Results: Patients with MADIT II characteristics and sinus rhythm had a microvolt T-wave alternans exercise test and a 12-lead ECG. Our primary end point was 2-year all-cause mortality. Of 177 MADIT II-like patients, 32% had a QRS duration >120 ms, and 68% had an abnormal (positive or indeterminate) microvolt T-wave alternans test. During an average follow-up of 20+/-6 months, 20 patients died. We compared patients with an abnormal microvolt T-wave alternans test to those with a normal (negative) test, and patients with a QRS >120 ms with those with a QRS < or =120 ms; the hazard ratios for 2-year mortality were 4.8 (P=0.020) and 1.5 (P=0.367), respectively. The actuarial mortality rate was substantially lower among patients with a normal microvolt T-wave alternans test (3.8%; 95% confidence interval: 0, 9.0) than the mortality rate in patients with a narrow QRS (12.0%; 95% confidence interval: 5.6, 18.5). The corresponding false-negative rates are 3.5% and 10.2%, respectively.

Conclusions: Among MADIT II-like patients, a microvolt T-wave alternans test is better than QRS duration at identifying a high-risk group and also better at identifying a low-risk group unlikely to benefit from ICD therapy.

Citing Articles

Clinical phenotypes in acute and chronic infarction explained through human ventricular electromechanical modelling and simulations.

Zhou X, Wang Z, Camps J, Tomek J, Santiago A, Quintanas A Elife. 2024; 13.

PMID: 39711335 PMC: 11668532. DOI: 10.7554/eLife.93002.


Hypoxaemic load in sleep apnoea is associated with acute changes in T-wave amplitude.

Sillanmaki S, Ebrahimian S, Hietakoste S, Hernando D, Bailon R, Leppanen T ERJ Open Res. 2024; 10(5).

PMID: 39469266 PMC: 11514031. DOI: 10.1183/23120541.00341-2024.


Lack of Prognostic Value of T-Wave Alternans for Implantable Cardioverter-Defibrillator Benefit in Primary Prevention.

Pelli A, Kentta T, Junttila M, Huber C, Schlogl S, Zabel M J Am Heart Assoc. 2024; 13(11):e032465.

PMID: 38804218 PMC: 11255625. DOI: 10.1161/JAHA.123.032465.


T-Wave Analysis on the 24 h Holter ECG Monitoring as a Predictive Assessment of Major Adverse Cardiovascular Events in Patients with Myocardial Infarction: A Literature Review and Future Perspectives.

Duca S, Roca M, Costache A, Chetran A, Afrasanie I, Miftode R Life (Basel). 2023; 13(5).

PMID: 37240799 PMC: 10222557. DOI: 10.3390/life13051155.


Heart rate variability and microvolt T wave alternans changes during ajmaline test may predict prognosis in Brugada syndrome.

Calburean P, Pannone L, Sorgente A, Gauthey A, Monaco C, Strazdas A Clin Auton Res. 2023; 33(1):51-62.

PMID: 36645559 DOI: 10.1007/s10286-023-00922-4.