» Articles » PMID: 15364266

Comparison of Binax NOW and Directigen for Rapid Detection of Influenza A and B

Overview
Journal J Clin Virol
Specialty Microbiology
Date 2004 Sep 15
PMID 15364266
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Directigen Flu A + B and Binax NOW Flu A and Flu B tests detected 33 (55.9%) and 31 (52.5%) of 59 influenza-positive samples, respectively. In children under 2 years of age, sensitivity increased to 75% for both tests. Three samples tested falsely-positive for influenza B using Binax NOW.

Citing Articles

Highly Sensitive and Specific Detection of Influenza A Viruses Using Bimolecular Fluorescence Complementation (BiFC) Reporter System.

Lee U, Oh Y, Kwon O, Shin Y, Kim M Biosensors (Basel). 2023; 13(8).

PMID: 37622868 PMC: 10452828. DOI: 10.3390/bios13080782.


[Diagnosis of viral respiratory infections].

Leruez-Ville M Rev Fr Allergol Immunol Clin. 2020; 46(6):538-542.

PMID: 32287959 PMC: 7143589. DOI: 10.1016/j.allerg.2006.09.001.


Laboratory diagnosis of viral infection.

Peaper D, Landry M Handb Clin Neurol. 2014; 123:123-47.

PMID: 25015483 PMC: 7151872. DOI: 10.1016/B978-0-444-53488-0.00005-5.


Evaluation of a new rapid antigen test using immunochromatography for detection of human metapneumovirus in comparison with real-time PCR assay.

Matsuzaki Y, Takashita E, Okamoto M, Mizuta K, Itagaki T, Katsushima F J Clin Microbiol. 2009; 47(9):2981-4.

PMID: 19571031 PMC: 2738101. DOI: 10.1128/JCM.00321-09.


The limitations of point of care testing for pandemic influenza: what clinicians and public health professionals need to know.

Hatchette T, Bastien N, Berry J, Booth T, Chernesky M, Couillard M Can J Public Health. 2009; 100(3):204-7.

PMID: 19507723 PMC: 6973943.