» Articles » PMID: 15326044

16-detector Multislice CT: Dosimetry Estimation by TLD Measurement Compared with Monte Carlo Simulation

Overview
Journal Br J Radiol
Specialty Radiology
Date 2004 Aug 25
PMID 15326044
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Computer simulations are widely used to estimate effective doses from CT examinations. The raw data often used in their estimations were obtained some years ago and made certain assumptions regarding CT unit design. At that time multidetector CT units were unavailable. Changes in design will limit the accuracy of computer simulated dosimetry on these machines. We therefore estimated CT dose on a 16-detector unit directly using thermoluminescent dosemeters (TLDs) and an anthropomorphic phantom. We found that the dose measured directly was 18% higher than the computer simulated dosimetry, in keeping with the previously recognised underestimation by computer simulation techniques compared with TLD measurements.

Citing Articles

Prediction of breast dose in chest CT examinations using adaptive neuro-fuzzy inference system (ANFIS).

Bahonar B, Changizi V, Ebrahiminia A, Baradaran S Phys Eng Sci Med. 2023; 46(3):1071-1080.

PMID: 37245194 PMC: 10225119. DOI: 10.1007/s13246-023-01276-x.


Utilization of artificial intelligence approach for prediction of DLP values for abdominal CT scans: A high accuracy estimation for risk assessment.

Tekin H, Almisned F, Erguzel T, Abuzaid M, Elshami W, Ene A Front Public Health. 2022; 10:892789.

PMID: 35968466 PMC: 9366721. DOI: 10.3389/fpubh.2022.892789.


Can Common Lead Apron in Testes Region Cause Radiation Dose Reduction during Chest CT Scan? A Patient Study.

Kiapour M, Ebrahimnejad Gorji K, Mehraeen R, Ghaemian N, Niksirat Sustani F, Abedi-Firouzjah R J Biomed Phys Eng. 2021; 11(4):497-504.

PMID: 34458197 PMC: 8385221. DOI: 10.31661/jbpe.v0i0.2104-1307.


Can ultrasound guidance reduce radiation exposure significantly in percutaneous nephrolithotomy in pediatric patients?.

Bayram Ilikan G, Karabulut B, Tiryaki H Urolithiasis. 2021; 49(2):173-180.

PMID: 33416916 DOI: 10.1007/s00240-020-01241-3.


Using body mass index to estimate individualised patient radiation dose in abdominal computed tomography.

ONeill S, Kavanagh R, Carey B, Moore N, Maher M, OConnor O Eur Radiol Exp. 2018; 2(1):38.

PMID: 30483977 PMC: 6258803. DOI: 10.1186/s41747-018-0070-5.