Hypotensive Resuscitation of Multiple Hemorrhages Using Crystalloid and Colloids

Overview
Journal Shock
Date 2004 Aug 19
PMID 15316397
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Hypotensive resuscitation has been advocated as a better means to perform field resuscitation of penetrating trauma. Our hypothesis is that hypotensive resuscitation using either crystalloid or colloid provides equivalent or improved metabolic function while reducing the overall fluid requirement for resuscitation of hemorrhage. We compared hypotensive and normotensive resuscitation of hemorrhage using lactated Ringer's (LR) with hypotensive resuscitation using Hextend (Hex), 6% hetastarch in isotonic buffered saline. Instrumented conscious sheep were hemorrhaged in three separate bleeds, 25 mL/kg at T0 and 5 mL/kg at both T50 and T70. Resuscitation was started at T30 and continued until T180. Hypotensive resuscitation to a mean arterial pressure (MAP) of 65 mmHg was performed with LR or Hex using a closed-loop resuscitation (CLR) system for a LR-65 and Hex-65 treatment protocol. A control treatment protocol was resuscitation with LR to a MAP target of 90 mmHg, LR-90. All treatment protocols were successfully resuscitated to near target levels. Two animals in the hypotensive treatment protocols died during the second and third bleedings, one in the LR-65 and one in the Hex-65 treatment protocol. Mean infused volumes were 61.4 +/- 11.3, 18.0 +/- 5.9, and 11.6 +/- 1.9 mL/kg in the LR-90, LR-65, and Hex-65 treatments, respectively (*P < 0.05 versus LR-90). Mean minimum base excess (BE) values were +1.9 +/- 1.4, -5.8 +/- 4.3, and -5.9 +/- 4.0 mEq/L in the LR-90, LR-65, and Hex-65 treatments, respectively. Hypotensive resuscitation with LR greatly reduced volume requirements as compared with normotensive resuscitation, and Hex achieved additional volume sparing. However, trends toward lower BE values and the occurrence of deaths only in the hypotensive treatment protocols suggest that resuscitation to a target MAP of 65 mmHg may be too low for optimal outcomes.

Citing Articles

Safe automation of interfering medical treatments via control barrier functions and reachability analysis: a fluid resuscitation-sedation-vasopressor infusion case study.

Yin W, Fathy H, Hahn J J Clin Monit Comput. 2025; .

PMID: 40050565 DOI: 10.1007/s10877-025-01270-6.


Detection of Internal Hemorrhage via Sequential Inference: An In Silico Feasibility Study.

Chalumuri Y, Jin X, Tivay A, Hahn J Diagnostics (Basel). 2024; 14(17).

PMID: 39272754 PMC: 11394393. DOI: 10.3390/diagnostics14171970.


A Lumped-Parameter Model of the Cardiovascular System Response for Evaluating Automated Fluid Resuscitation Systems.

Chalumuri Y, Arabidarrehdor G, Tivay A, Sampson C, Khan M, Kinsky M IEEE Access. 2024; 12:62511-62525.

PMID: 38872754 PMC: 11170980. DOI: 10.1109/access.2024.3395008.


Credibility Assessment of a Subject-Specific Mathematical Model of Blood Volume Kinetics for Prediction of Physiological Response to Hemorrhagic Shock and Fluid Resuscitation.

Parvinian B, Bighamian R, Scully C, Hahn J, Pathmanathan P Front Physiol. 2021; 12:705222.

PMID: 34603074 PMC: 8481867. DOI: 10.3389/fphys.2021.705222.


Accuracy assessment methods for physiological model selection toward evaluation of closed-loop controlled medical devices.

Bighamian R, Hahn J, Kramer G, Scully C PLoS One. 2021; 16(4):e0251001.

PMID: 33930095 PMC: 8087034. DOI: 10.1371/journal.pone.0251001.