» Articles » PMID: 15311818

Establishment of a Knee-joint Coordinate System from Helical Axes Analysis--a Kinematic Approach Without Anatomical Referencing

Overview
Date 2004 Aug 18
PMID 15311818
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

This study establishes a functional knee-joint coordinate system (FCS) derived from active motion. The scale invariant properties of helical axes were used in order to avoid inter-observer errors associated with the traditional anatomical referencing techniques. The algorithm was tested with six cadaveric specimens in a knee-joint motion and loading apparatus. To determine the FCS sensitivity to variable loading, rotational moments were applied to the tibia while extending and flexing the knee. Each derived FCS was compared with the clinically derived anatomical coordinate system (ACS). The FCS was reproducible when the loading condition was the same. Changing the rotational moments from internal to external affected the orientations and the positions of the FCS. The largest displacement of 20.8 mm in average occurred in the medio/lateral direction. The FCS corresponded with the ACS for all specimens and loading conditions. The origin was always located within the femur along the transepicondylar line. The orientations differed less than 16.6 degrees in average, thus allowing the use of clinical terminology. These findings suggest that the FCS might improve the ability to clinically assess kinematic alterations provided that the reference motion is reproducible.

Citing Articles

Validation of a Biomechanical Injury and Disease Assessment Platform Applying an Inertial-Based Biosensor and Axis Vector Computation.

Kim W, Vela E, Kohles S, Huayamave V, Gonzalez O Electronics (Basel). 2023; 12(17).

PMID: 37974898 PMC: 10653259. DOI: 10.3390/electronics12173694.


Effect of the soft tissue artifact on marker measurements and on the calculation of the helical axis of the knee during a squat movement: A study on the CAMS-Knee dataset.

Ancillao A, Aertbelien E, De Schutter J Med Eng Phys. 2022; 110:103915.

PMID: 36564140 PMC: 9771824. DOI: 10.1016/j.medengphy.2022.103915.


The helical axis of anatomical joints: calculation methods, literature review, and software implementation.

Ancillao A Med Biol Eng Comput. 2022; 60(7):1815-1825.

PMID: 35553355 DOI: 10.1007/s11517-022-02576-2.


Articulation of the femoral condyle during knee flexion.

Li G, Zhou C, Zhang Z, Foster T, Bedair H J Biomech. 2021; 131:110906.

PMID: 34923296 PMC: 8760888. DOI: 10.1016/j.jbiomech.2021.110906.


Effect of the soft tissue artifact on marker measurements and on the calculation of the helical axis of the knee during a gait cycle: A study on the CAMS-Knee data set.

Ancillao A, Aertbelien E, De Schutter J Hum Mov Sci. 2021; 80:102866.

PMID: 34509901 PMC: 8631460. DOI: 10.1016/j.humov.2021.102866.