» Articles » PMID: 15216223

Noninvasive Assessment of the Stenotic Mitral Valve Orifice by Two-dimensional Echocardiography

Overview
Journal Cardiovasc Dis
Date 1981 Mar 1
PMID 15216223
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Two-dimensional echocardiographic imaging of the mitral valve orifice was attempted in 26 patients with isolated mitral stenosis. The intention was to examine further the clinical usefulness and limitations of this technique for estimating the severity of mitral stenosis. Technically adequate recordings of the mitral orifice were obtained in 20 patients (77%). Mitral valve area calculated from echocardiography compared favorably to the valve area derived from cardiac catheterization with the use of the Gorlin formula (r = 0.95). The average difference between the two methods was 0.109 cm(2). Two-dimensional echocardiography does provide clinically useful data for predicting the degree of mitral stenosis in the majority of patients provided that critical technical limitations are recognized.

Citing Articles

Assessment of rheumatic mitral valve disease. Value of echocardiography in patients clinically suspected of predominant stenosis.

Egeblad H, Berning J, Saunamaki K, Jacobsen J, WENNEVOLD A Br Heart J. 1983; 49(1):38-44.

PMID: 6821609 PMC: 485208. DOI: 10.1136/hrt.49.1.38.

References
1.
Wann L, Weyman A, FEIGENBAUM H, Dillon J, Johnston K, EGGLETON R . Determination of mitral valve area by cross-sectional echocardiography. Ann Intern Med. 1978; 88(3):337-41. DOI: 10.7326/0003-4819-88-3-337. View

2.
Nichol P, GILBERT B, Kisslo J . Two-dimensional echocardiographic assessment of mitral stenosis. Circulation. 1977; 55(1):120-8. DOI: 10.1161/01.cir.55.1.120. View

3.
Henry W, Griffith J, Michaelis L, MCINTOSH C, Morrow A, Epstein S . Measurement of mitral orifice area in patients with mitral valve disease by real-time, two-dimensional echocardiography. Circulation. 1975; 51(5):827-31. DOI: 10.1161/01.cir.51.5.827. View

4.
Wharton C, Bescos L . Mitral valve movement: a study using an ultrasound technique. Br Heart J. 1970; 32(3):344-9. PMC: 487331. DOI: 10.1136/hrt.32.3.344. View

5.
Cope G, Kisslo J, Johnson M, BEHAR V . A reassessment of the echocardiogram in mitral stenosis. Circulation. 1975; 52(4):664-70. DOI: 10.1161/01.cir.52.4.664. View