Abstract

We describe a new fluorescence imaging methodology in which the image contrast is derived from the fluorescence lifetime at each point in a two-dimensional image and not the local concentration and/or intensity of the fluorophore. In the present apparatus, lifetime images are created from a series of images obtained with a gain-modulated image intensifier. The frequency of gain modulation is at the light-modulation frequency (or a harmonic thereof), resulting in homodyne phase-sensitive images. These stationary phase-sensitive images are collected using a slow-scan CCD camera. A series of such images, obtained with various phase shifts of the gain-modulation signal, is used to determine the phase angle and/or modulation of the emission at each pixel, which is in essence the phase or modulation lifetime image. An advantage of this method is that pixel-to-pixel scanning is not required to obtain the images, as the information from all pixels is obtained at the same time. The method has been experimentally verified by creating lifetime images of standard fluorophores with known lifetimes, ranging from 1 to 10 ns. As an example of biochemical imaging we created life-time images of Yt-base when quenched by acrylamide, as a model for a fluorophore in distinct environments that affect its decay time. Additionally, we describe a faster imaging procedure that allows images in which a specific decay time is suppressed to be calculated, allowing rapid visualization of unique features and/or regions with distinct decay times. The concepts and methodologies of fluorescence lifetime imaging (FLIM) have numerous potential applications in the biosciences. Fluorescence lifetimes are known to be sensitive to numerous chemical and physical factors such as pH, oxygen, temperature, cations, polarity, and binding to macromolecules. Hence the FLIM method allows chemical or physical imaging of macroscopic and microscopic samples.

Citing Articles

Fluorescence lifetime imaging microscopy of endogenous fluorophores in health and disease.

Elsnicova B J Muscle Res Cell Motil. 2025; .

PMID: 39946024 DOI: 10.1007/s10974-025-09689-9.


Revealing mitochondrial architecture and functions with single molecule localization microscopy.

Jolivet N, Bertolin G Biol Cell. 2025; 117(1):e2400082.

PMID: 39877953 PMC: 11775716. DOI: 10.1111/boc.202400082.


Two-photon NAD(P)H-FLIM reveals unperturbed energy metabolism of Ascaris suum larvae, in contrast to host macrophages upon artemisinin derivatives exposure.

Musimbi Z, Kundik A, Krucken J, Hauser A, Rausch S, Seeberger P Sci Rep. 2025; 15(1):2056.

PMID: 39814779 PMC: 11735674. DOI: 10.1038/s41598-025-85780-y.


Imaging-Based Molecular Interaction Between Src and Lamin A/C Mechanosensitive Proteins in the Nucleus of Laminopathic Cells.

Petrini S, Bagnato G, Piccione M, DOria V, Apollonio V, Cappa M Int J Mol Sci. 2025; 25(24.

PMID: 39769130 PMC: 11678420. DOI: 10.3390/ijms252413365.


To label or not: the need for validation in label-free imaging.

Szulczewski J, Yesilkoy F, Ulland T, Bartels R, Millis B, Boppart S J Biomed Opt. 2024; 29(Suppl 2):S22717.

PMID: 39711795 PMC: 11660684. DOI: 10.1117/1.JBO.29.S2.S22717.


References
1.
Rigler R, Wintermeyer W . Dynamics of tRNA. Annu Rev Biophys Bioeng. 1983; 12:475-505. DOI: 10.1146/annurev.bb.12.060183.002355. View

2.
RUMSEY W, Vanderkooi J, Wilson D . Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue. Science. 1988; 241(4873):1649-51. DOI: 10.1126/science.241.4873.1649. View

3.
Gryczynski I, Johnson M, Lakowicz J . Acrylamide quenching of Yt-base fluorescence in aqueous solution. Biophys Chem. 1988; 31(3):269-74. DOI: 10.1016/0301-4622(88)80032-2. View

4.
Tsien R, Pozzan T . Measurement of cytosolic free Ca2+ with quin2. Methods Enzymol. 1989; 172:230-62. DOI: 10.1016/s0076-6879(89)72017-6. View

5.
Lakowicz J, Cherek H, Balter A . Correction of timing errors in photomultiplier tubes used in phase-modulation fluorometry. J Biochem Biophys Methods. 1981; 5(3):131-46. DOI: 10.1016/0165-022x(81)90012-9. View