Energetics of Middle-distance Running Performances in Male and Female Junior Using Track Measurements
Overview
Affiliations
The aim of this study was to determine the energetic factors of middle-distance running performance in junior elite runners according to gender and by using measurements from on-track performances. Fifteen elite runners (8 males and 7 females) were investigated by means of an incremental test and an all-out run over 600 m performed with a 2-d interval. We calculated (1) the aerobic maximal power (E(r max aero), in W kg(-1)), including VO(2 max) and the delay of attainment of VO(2 max) in the 600 m run; (2) the anaerobic power (E(r max anaero)), i.e., the oxygen deficit (J kg(-1)) divided by the duration of the 600 m run. Despite the difference in race duration (87 +/- 3 vs. 102 +/- 2 s), the 600 m run was made at the same relative value of the velocity associated with VO(2 max) (VVO(2 )max) in males and females (121.6 +/- 7 vs. 120 +/- 8% VO(2 max), p = 0.7). E(r max aero) explained most of the variance in the performance (the personal best performed 8 weeks later) between genders: 65 and 79% over 800 m (T(800)) and 1,500 m (T(1,500)). For females, E(r max aero) explained most of the variance of T(1,500) (r(2) = 0.66), and E(r max anaero) improved this prediction (r(2) = 0.84). No energetic factor predicted the performance on 800 m run in males. In elite junior athletes, the energetic model with individual data measured over an all-out 600 m performed on a track, provides an explanation for most of the variance in middle-distance running performances between genders. The distinction between aerobic power and anaerobic power allowed an improvement in the prediction of middle-distance running performances.
Anthropometric Characteristics, Body Composition and Somatotype of Elite Male Young Runners.
Sanchez Munoz C, Muros J, Lopez Belmonte O, Zabala M Int J Environ Res Public Health. 2020; 17(2).
PMID: 31968680 PMC: 7013868. DOI: 10.3390/ijerph17020674.
Turnes T, Felix Salvador A, Lisboa F, de Aguiar R, Cruz R, Caputo F PLoS One. 2014; 9(10):e111621.
PMID: 25360744 PMC: 4216092. DOI: 10.1371/journal.pone.0111621.
Determinants of performance in 1,500-m runners.
Ferri A, Adamo S, LA Torre A, Marzorati M, Bishop D, Miserocchi G Eur J Appl Physiol. 2011; 112(8):3033-43.
PMID: 22179856 DOI: 10.1007/s00421-011-2251-2.
Figard-Fabre H, Fabre N, Leonardi A, Schena F Eur J Appl Physiol. 2010; 108(6):1141-51.
PMID: 20091181 DOI: 10.1007/s00421-009-1315-z.