» Articles » PMID: 15173776

Automatic Quantification of Right Ventricular Function with Gated Blood Pool SPECT

Overview
Journal J Nucl Cardiol
Date 2004 Jun 3
PMID 15173776
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Quantification of right ventricular (RV) function is clinically relevant for the risk stratification and follow-up of patients with a wide spectrum of disease. This can be achieved with electrocardiography-gated blood pool single photon emission computed tomography (GBPS). We aimed to evaluate the accuracy of the completely automatic QBS GBPS processing software as compared with equilibrium planar radionuclide angiography (RNA) and with a GBPS manual segmentation method (GBPS(35%)) for the measurement of global RV ejection fraction (EF), taking the first-pass RNA (FP-RNA) as the gold standard. In parallel, we compared the RVEF, RV end-diastolic volume (EDV), and RV end-systolic volume (ESV) provided by QBS and GBPS(35%).

Methods And Results: The population included 85 patients with chronic post-embolic pulmonary hypertension. Twenty-one patients were excluded because of unsuccessful FP-RNA. Intraobserver and interobserver RVEF, RVEDV, and RVESV reproducibilities encountered with planar RNA, QBS, and GBPS(35%) were similar and compared favorably with those calculated with FP-RNA for RVEF. Mean RVEF was different between all methods. RVEF calculated with FP-RNA was better correlated to QBS (r = 0.68) and GBPS(35%) (r = 0.70) than to planar RNA (r = 0.59). RVEDV and RVESV with QBS were lower than with GBPS(35%), by 29% +/- 14% and 36% +/- 13%, respectively. RVEDV and RVESV with QBS were highly correlated to corresponding GBPS(35%) values: r = 0.88 and r = 0.91, respectively.

Conclusion: As opposed to FP-RNA, GBPS is highly successful for the quantification of RV function. Both QBS and GBPS(35%) provide RVEF values similarly well correlated to FP-RNA and performed better than planar RNA. RVEF, RVEDV, and RVESV provided by QBS and GBPS(35%) are highly correlated. All of these RV functional measurements require further validation versus a better gold standard before their accuracy can be established.

Citing Articles

Evaluation of biventricular function by cadmium-zinc-telluride SPECT gated tomographic radionuclide angiography: Comparison to conventional SPECT.

Chen Y, Pang Z, Wang J, Yang X, Li J Medicine (Baltimore). 2024; 103(39):e39821.

PMID: 39331918 PMC: 11441949. DOI: 10.1097/MD.0000000000039821.


Non-invasive imaging techniques for early diagnosis of bilateral cardiac dysfunction in pulmonary hypertension: current crests, future peaks.

Ahmad A, Zou Y, Zhang P, Li L, Wang X, Wang Y Front Cardiovasc Med. 2024; 11:1393580.

PMID: 38784167 PMC: 11112117. DOI: 10.3389/fcvm.2024.1393580.


Assessment and diagnosis of right ventricular failure-retrospection and future directions.

Kyun Ro S, Sato K, Ijuin S, Sela D, Fior G, Heinsar S Front Cardiovasc Med. 2023; 10:1030864.

PMID: 37324632 PMC: 10268009. DOI: 10.3389/fcvm.2023.1030864.


QCard-NM: Developing a semiautomatic segmentation method for quantitative analysis of the right ventricle in non-gated myocardial perfusion SPECT imaging.

Entezarmahdi S, Faghihi R, Yazdi M, Shahamiri N, Geramifar P, Haghighatafshar M EJNMMI Phys. 2023; 10(1):21.

PMID: 36959409 PMC: 10036722. DOI: 10.1186/s40658-023-00539-6.


Heart Rate Expenditure Correlates with Right Ventricular Function.

Lachant D, Light A, Mackin M, Schwartz R, White R Ann Am Thorac Soc. 2019; 17(3):372-375.

PMID: 31682767 PMC: 7047316. DOI: 10.1513/AnnalsATS.201909-683RL.


References
1.
Vera P, Gardin I, Bok B . Comparative study of three automatic programs of left ventricular ejection fraction evaluation. Nucl Med Commun. 1995; 16(8):667-74. DOI: 10.1097/00006231-199508000-00008. View

2.
Lewczuk J, Piszko P, Jagas J, Porada A, Wojciak S, Sobkowicz B . Prognostic factors in medically treated patients with chronic pulmonary embolism. Chest. 2001; 119(3):818-23. DOI: 10.1378/chest.119.3.818. View

3.
Daou D, Harel F, Helal B, Fourme T, Colin P, Lebtahi R . Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation. J Nucl Med. 2001; 42(7):1043-9. View

4.
Chow L, Dittrich H, Hoit B, Moser K, Nicod P . Doppler assessment of changes in right-sided cardiac hemodynamics after pulmonary thromboendarterectomy. Am J Cardiol. 1988; 61(13):1092-7. DOI: 10.1016/0002-9149(88)90132-4. View

5.
Bartlett M, Srinivasan G, Barker W, Kitsiou A, Dilsizian V, Bacharach S . Left ventricular ejection fraction: comparison of results from planar and SPECT gated blood-pool studies. J Nucl Med. 1996; 37(11):1795-9. View