» Articles » PMID: 15155506

Pacemaker Induced Ventricular Fibrillation in Coronary Care Units

Overview
Journal BMJ
Specialty General Medicine
Date 2004 May 25
PMID 15155506
Citations 5
Authors
Affiliations
Soon will be listed here.
Citing Articles

Complications associated with the use of temporary pacemaker in patients waiting for definitive device implantation.

Papp S, Torres A, Vasquez A, Gioli-Pereira L Einstein (Sao Paulo). 2022; 20:eAO8013.

PMID: 35766673 PMC: 9239569. DOI: 10.31744/einstein_journal/2022AO8013.


Perioperative Management of Patients with Cardiac Implantable Electronic Devices and Utility of Magnet Application.

Ozkartal T, Demarchi A, Caputo M, Baldi E, Conte G, Auricchio A J Clin Med. 2022; 11(3).

PMID: 35160149 PMC: 8836758. DOI: 10.3390/jcm11030691.


Masked premature ventricular contractions and intradevice interaction causing ventricular fibrillation.

Do D, Meyer S, Bradfield J, Shivkumar K, Boyle N, Khakpour H HeartRhythm Case Rep. 2021; 7(2):69-73.

PMID: 33665104 PMC: 7897743. DOI: 10.1016/j.hrcr.2020.11.002.


Recurrent Postmyocardial Infarction Ventricular Tachycardia: An Unusual Culprit.

Sharma A, Jain N, Safal S, Kumar V, Dwivedi S Case Rep Cardiol. 2015; 2015:564394.

PMID: 26682074 PMC: 4670629. DOI: 10.1155/2015/564394.


Immediate and 12 months follow up of function and lead integrity after cranial MRI in 356 patients with conventional cardiac pacemakers.

Muehling O, Wakili R, Greif M, von Ziegler F, Morhard D, Brueckmann H J Cardiovasc Magn Reson. 2014; 16:39.

PMID: 24903354 PMC: 4053551. DOI: 10.1186/1532-429X-16-39.

References
1.
CHARDACK W, Ishikawa H, Fochler F, Souther S, Gage A . Pacing and ventricular fibrillation. Ann N Y Acad Sci. 1969; 167(2):919-33. DOI: 10.1111/j.1749-6632.1969.tb34154.x. View

2.
Preston T . Anodal stimulation as a cause of pacemaker-induced ventricular fibrillation. Am Heart J. 1973; 86(3):366-72. DOI: 10.1016/0002-8703(73)90046-x. View

3.
Sallam I . Induced ventricular tachycardia and fibrillation by a fixed rate pacemaker. The fibrillation threshold in humans. Case report. J Cardiovasc Surg (Torino). 1973; 14(4):443-5. View

4.
Seipel L, Bub E, LOOGEN F . Ventricular fibrillation induced by a unipolar implanted pacemaker (cathodal stimulation). Am Heart J. 1976; 92(6):810-1. DOI: 10.1016/s0002-8703(76)80024-5. View

5.
Mooss A, ROSS W, Esterbrooks D, Nair C, Mohiuddin S, SKETCH M . Ventricular fibrillation complicating pacemaker insertion in acute myocardial infarction. Cathet Cardiovasc Diagn. 1982; 8(3):253-9. DOI: 10.1002/ccd.1810080307. View