Servo-controlled Pneumatic Pressure Oscillator for Respiratory Impedance Measurements and High-frequency Ventilation
Overview
Authors
Affiliations
The ability to provide forced oscillatory excitation of the respiratory system can be useful in mechanical impedance measurements as well as high frequency ventilation (HFV). Experimental systems currently used for generating forced oscillations are limited in their ability to provide high amplitude flows or maintain the respiratory system at a constant mean pressure during excitation. This paper presents the design and implementation of a pneumatic pressure oscillator based on a proportional solenoid valve. The device is capable of providing forced oscillatory excitations to the respiratory system over a bandwidth suitable for mechanical impedance measurements and HVF. It delivers high amplitude flows (> 1.4 l/s) and utilizes a servo-control mechanism to maintain a load at a fixed mean pressure during simultaneous oscillation. Under open-loop conditions, the device exhibited a static hysteresis of approximately 7%, while its dynamic magnitude and phase responses were flat out to 10 Hz. Broad-band measurement of total harmonic distortion was approximately 19%. Under closed-loop conditions, the oscillator was able to maintain a mechanical test load at both positive and negative mean pressures during oscillatory excitations from 0.1 to 10.0 Hz. Impedance of the test load agreed closely with theoretical predictions. We conclude that this servo-controlled oscillator can be a useful tool for respiratory impedance measurements as well as HFV.
Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator.
Cruz A, Herrmann J, Hajdarevic B, Hawley M, Fox D, Bates J J Med Device. 2024; 19(1):011001.
PMID: 39464246 PMC: 11500807. DOI: 10.1115/1.4066679.
Lung function measurements in preclinical research: What has been done and where is it headed?.
Ahookhosh K, Vanoirbeek J, Velde G Front Physiol. 2023; 14:1130096.
PMID: 37035677 PMC: 10073442. DOI: 10.3389/fphys.2023.1130096.
Cruz A, Herrmann J, Carvalho C, Kaczka D J Clin Monit Comput. 2021; 36(5):1461-1477.
PMID: 34910285 PMC: 9198108. DOI: 10.1007/s10877-021-00788-9.
System identification of proportional solenoid valve dynamics.
Hajdarevic B, Herrmann J, Fonseca da Cruz A, Kaczka D Int J Model Identif Control. 2020; 34(2):103-115.
PMID: 33184571 PMC: 7654981. DOI: 10.1504/ijmic.2020.10032851.
Herrmann J, Gerard S, Shao W, Hawley M, Reinhardt J, Christensen G Front Physiol. 2020; 11:14.
PMID: 32153417 PMC: 7044245. DOI: 10.3389/fphys.2020.00014.