Managing Instability in Total Knee Arthroplasty with Constrained and Linked Implants

Overview
Specialty Orthopedics
Date 2004 May 1
PMID 15116615
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Instability is a relatively common cause of failure of total knee arthroplasty. In the management of the unstable total knee, the need for constraint must be anticipated. Careful preoperative planning including history and physical examination of the ligamentous support of the knee is mandatory. A thorough study of current and previous radiographs is important to determine wear, component migration, and bone loss. As a general rule, it is recommended that the minimum amount of constraint necessary to achieve stability should be used. Most of the time, stability can be achieved using a posterior-stabilized or a nonlinked implant, such as a varus-valgus constrained or constrained-condylar knee implant. Occasionally, a hinge prosthesis may be indicated, particularly in a patient with an absent and nonreconstructable medial collateral ligament. Increasing constraint is not without its problems, however, as forces across the knee may be transmitted to the stem-bone interface, resulting in radiographic loosening of stemmed components. Fortunately, these observations of radiographic loosening around stems of revision components have not so far correlated with reports of clinical failure.

Citing Articles

Management of Iatrogenic Medial Collateral Ligament Injury in Primary Total Knee Arthroplasty: A Systematic Review.

Amiri S, Mirahmadi A, Parvandi A, Hosseini-Monfared P, Minaei Noshahr R, Hoseini S Arch Bone Jt Surg. 2024; 12(3):159-166.

PMID: 38577515 PMC: 10989723. DOI: 10.22038/ABJS.2023.73563.3406.


Primary constrained condylar knee arthroplasty in severe varus deformity: a prospective 5-year functional follow-up study in Iraqi patients.

Alqatub A, Hasan G, Wahab M, Katran M, Wais Y, Masaoodi A Eur J Orthop Surg Traumatol. 2023; 33(3):459-463.

PMID: 36592240 DOI: 10.1007/s00590-022-03470-1.


Long-term outcomes of one single-design varus valgus constrained versus one single-design rotating hinge in revision knee arthroplasty after over 10-year follow-up.

Sanz-Ruiz P, Leon-Roman V, Matas-Diez J, Villanueva-Martinez M, Vaquero J J Orthop Surg Res. 2022; 17(1):135.

PMID: 35246182 PMC: 8896104. DOI: 10.1186/s13018-022-03026-3.


Management of Medial Collateral Ligament Insufficiency During Total Knee Arthroplasty with a Screw and Rectangular Spiked Washer: A Case Series of 14 Patients.

Ni M, Sun J, Fu J, Du Y, Shen J, Yang X Orthop Surg. 2020; 12(6):1784-1791.

PMID: 33063440 PMC: 7767681. DOI: 10.1111/os.12818.


Good clinical and radiological results of total knee arthroplasty using varus valgus constrained or rotating hinge implants in ligamentous laxity.

Rohner E, Benad K, Zippelius T, Kloss N, Jacob B, Kirschberg J Knee Surg Sports Traumatol Arthrosc. 2018; 27(5):1665-1670.

PMID: 30456570 DOI: 10.1007/s00167-018-5307-6.