Concerns have been raised over alleged overuse of CT scanning and inappropriate selection of scanning methods, all of which expose patients to unnecessary radiation. Thus, it is important to identify clinical situations in which techniques with lower radiation dose such as plain radiography or no radiation such as MRI and occasionally ultrasonography can be chosen over CT scanning. This article proposes the arguments for radiation dose reduction in CT scanning of the chest and discusses recommended practices and studies that address means of reducing radiation exposure associated with CT scanning of the chest.

Citing Articles

Straight-to-Test Pathway in Faecal Immunochemical Testing (FIT)-Negative Patients: A Cost-Effective Approach.

Boulbadaoui A, Rashid M, Nair N, Mohamed G, Poh S, Britton I Cureus. 2024; 16(11):e73464.

PMID: 39529920 PMC: 11554240. DOI: 10.7759/cureus.73464.


Development and Validation of an Artificial Intelligence Model for Detecting Rib Fractures on Chest Radiographs.

Lee K, Lee S, Kwak J, Park H, Oh H, Koh J J Clin Med. 2024; 13(13).

PMID: 38999416 PMC: 11242496. DOI: 10.3390/jcm13133850.


Do Ultrasound Lung Abnormalities Correlate to Biomarkers and Male Gender in Rheumatoid Arthritis Patients? A Monocentric Cross-Sectional Study.

Bandinelli F, Benucci M, Mallia I, Mauro I, Pecani N, Li Gobbi F J Clin Med. 2024; 13(12).

PMID: 38930065 PMC: 11204435. DOI: 10.3390/jcm13123534.


3D Single-Breath Chemical Shift Imaging Hyperpolarized Xe-129 MRI of Healthy, CF, IPF, and COPD Subjects.

Guan S, Tustison N, Qing K, Shim Y, Mugler 3rd J, Altes T Tomography. 2022; 8(5):2574-2587.

PMID: 36287814 PMC: 9607398. DOI: 10.3390/tomography8050215.


The influence of contrast enhancement and experience of observers on the assessment of mediastinal lymph nodes in sarcoidosis patients.

Sobocinska M, Bialecki M, Sobocinski B, Martynowska I, Ciescinski J Pol J Radiol. 2022; 87:e392-e396.

PMID: 35979152 PMC: 9373862. DOI: 10.5114/pjr.2022.118303.


References
1.
Lucaya J, Piqueras J, Garcia-Pena P, Enriquez G, Sotil J . Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality. AJR Am J Roentgenol. 2000; 175(4):985-92. DOI: 10.2214/ajr.175.4.1750985. View

2.
Kauczor H, Heussel C, Schreiber W, Kreitner K . [New developments in MRI of the thorax]. Radiologe. 2001; 41(3):279-87. DOI: 10.1007/s001170050988. View

3.
Diederich S, Wormanns D, Heindel W . Low-dose CT: new tool for screening lung cancer?. Eur Radiol. 2001; 11(10):1916-24. DOI: 10.1007/s003300100952. View

4.
Mayo J, Whittall K, Leung A, Hartman T, Park C, Primack S . Simulated dose reduction in conventional chest CT: validation study. Radiology. 1997; 202(2):453-7. DOI: 10.1148/radiology.202.2.9015073. View

5.
Karabulut N, Martin D, Yang M, Tallaksen R . MR imaging of the chest using a contrast-enhanced breath-hold modified three-dimensional gradient-echo technique: comparison with two-dimensional gradient-echo technique and multidetector CT. AJR Am J Roentgenol. 2002; 179(5):1225-33. DOI: 10.2214/ajr.179.5.1791225. View