» Articles » PMID: 15065251

Parallel Excitation with an Array of Transmit Coils

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2004 Apr 6
PMID 15065251
Citations 232
Authors
Affiliations
Soon will be listed here.
Abstract

Theoretical and experimental results are presented that establish the value of parallel excitation with a transmit coil array in accelerating excitation and managing RF power deposition. While a 2D or 3D excitation pulse can be used to induce a multidimensional transverse magnetization pattern for a variety of applications (e.g., a 2D localized pattern for accelerating spatial encoding during signal acquisition), it often involves the use of prolonged RF and gradient pulses. Given a parallel system that is composed of multiple transmit coils with corresponding RF pulse synthesizers and amplifiers, the results suggest that by exploiting the localization characteristics of the coils, an orchestrated play of shorter RF pulses can achieve desired excitation profiles faster without adding strains to gradients. A closed-form design for accelerated multidimensional excitations is described for the small-tip-angle regime, and its suppression of interfering aliasing lobes from coarse excitation k-space sampling is interpreted based on an analogy to sensitivity encoding (SENSE). With or without acceleration, the results also suggest that by taking advantage of the extra degrees of freedom inherent in a parallel system, parallel excitation provides better management of RF power deposition while facilitating the faithful production of desired excitation profiles. Sample accelerated and specific absorption rate (SAR)-reduced excitation pulses were designed in this study, and evaluated in experiments.

Citing Articles

Improving -inhomogeneity tolerance by resolving non-bijection in MP2RAGE R mapping: A 2D look-up table approach demonstrated at 3 T.

Ruijters L, Lund T, Vinding M Magn Reson Med. 2024; 93(4):1712-1722.

PMID: 39529499 PMC: 11782721. DOI: 10.1002/mrm.30363.


Parallel-transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water-selective excitation in the human brain at 7 T.

Shao X, Zhang Z, Ma X, Liu F, Guo H, Ugurbil K Magn Reson Med. 2024; 93(3):1238-1255.

PMID: 39481025 PMC: 11682926. DOI: 10.1002/mrm.30346.


Deep learning-based whole-brain B -mapping at 7T.

Krueger F, Aigner C, Lutz M, Riemann L, Degenhardt K, Hadjikiriakos K Magn Reson Med. 2024; 93(4):1700-1711.

PMID: 39462473 PMC: 11782730. DOI: 10.1002/mrm.30359.


Large improvement in RF magnetic fields and imaging SNR with whole-head high-permittivity slurry helmet for human-brain MRI applications at 7 T.

Soon S, Li X, Waks M, Zhu X, Wiesner H, Gandji N Magn Reson Med. 2024; 93(3):1205-1219.

PMID: 39449244 PMC: 11680740. DOI: 10.1002/mrm.30350.


Parallel transmit hybrid pulse design for controlled on-resonance magnetization transfer in R mapping at 7T.

Leitao D, Tomi-Tricot R, Bridgen P, Di Cio P, Liebig P, Gumbrecht R Magn Reson Med. 2024; 93(3):1090-1103.