Patient Size and X-ray Transmission in Body CT
Overview
Nuclear Medicine
Affiliations
Physical characteristics were obtained for 196 patients undergoing chest and abdomen computed tomography (CT) examinations. Computed tomography sections for these patients having no evident pathology were analyzed to determine patient dimensions (AP and lateral), together with the average attenuation coefficient. Patient weights ranged from approximately 3 kg to about 120 kg. For chest CT, the mean Hounsfield unit (HU) fell from about -120 HU for newborns to about -300 HU for adults. For abdominal CT, the mean HU for children and normal-sized adults was about 20 HU, but decreased to below -50 HU for adults weighing more than 100 kg. The effective photon energy and percent energy fluence transmitted through a given patient size and composition was calculated for representative x-ray spectra at 80, 100, 120, and 140 kV tube potentials. A 70-kg adult scanned at 120 kVp transmits 2.6% of the energy fluence for chest and 0.7% for abdomen CT examinations. Reducing the patient size to 10 kg increases transmission by an order of magnitude. For 70 kg patients, effective energies in body CT range from approximately 50 keV at 80 kVp to approximately 67 keV at 140 kVp; increasing patient size from 10 to 120 kg resulted in an increase in effective photon energy of approximately 4 keV. The x-ray transmission data and effective photon energy data can be used to determine CT image noise and image contrast, respectively, and information on patient size and composition can be used to determine patient doses.
Radiation Detectors and Sensors in Medical Imaging.
Michail C, Liaparinos P, Kalyvas N, Kandarakis I, Fountos G, Valais I Sensors (Basel). 2024; 24(19).
PMID: 39409289 PMC: 11478476. DOI: 10.3390/s24196251.
Internal calibration for opportunistic computed tomography muscle density analysis.
Smith A, Tse J, Waungana T, Bott K, Kuczynski M, Michalski A PLoS One. 2022; 17(10):e0273203.
PMID: 36251648 PMC: 9576101. DOI: 10.1371/journal.pone.0273203.
Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging.
De La Vega J, Esquinas P, Gill J, Jessa S, Gill B, Thakur Y Contrast Media Mol Imaging. 2021; 2021:1250360.
PMID: 34803544 PMC: 8575601. DOI: 10.1155/2021/1250360.
Extending the concept of weighted CT dose index to elliptical phantoms of various aspect ratios.
Markovich A, Morgan A, Dong F, Primak A, Li X J Med Imaging (Bellingham). 2017; 4(3):031205.
PMID: 28695156 PMC: 5497790. DOI: 10.1117/1.JMI.4.3.031205.
Ikuta I, Warden G, Andriole K, Khorasani R, Sodickson A Radiology. 2013; 270(2):472-80.
PMID: 24086075 PMC: 4228751. DOI: 10.1148/radiol.13122727.