Abstract

Quantitative analysis of facial volume is important in the assessment of facial swelling. Previous research has demonstrated that the Fiore trade mark light-structured 3-D range camera is a rapid, non-invasive, and safe imaging technology for the quantitative analysis of facial morphology. The development of the Rugle-3D trade mark volumetric measurement software programme has allowed for the development of a powerful imaging and measurement system. This study aimed to determine the accuracy and reproducibility of Fiore trade mark by measuring simulated facial swelling. A model involving 20 human subjects was devised to simulate facial swelling for image acquisition and measurement in order to assess the accuracy and reproducibility of the device. A systematic error of 1.25% and reproducibility of 3.27% was determined for the imaging system. It is concluded that Fiore trade mark is an accurate and reproducible technology that is sensitive and would be applicable to clinical studies of facial swelling.

Citing Articles

Automated pipeline for linear and volumetric assessment of facial swelling after third molar surgery.

Barone S, Zaffino P, Salviati M, Destito M, Antonelli A, Bennardo F BMC Oral Health. 2024; 24(1):1404.

PMID: 39563399 PMC: 11575084. DOI: 10.1186/s12903-024-05193-7.


Comparison of three-dimensional soft tissue changes according to the split pattern after sagittal split osteotomy in patients with skeletal class III malocclusion.

Yazaki M, Aihara T, Okamoto D, Saito S, Suzuki H, Nogami S Clin Oral Investig. 2023; 28(1):34.

PMID: 38147171 PMC: 10751263. DOI: 10.1007/s00784-023-05431-2.


Quality of Life of Patients after Kinesio Tape Applications Following Impacted Mandibular Third Molar Surgeries.

Jaron A, Preuss O, Konkol B, Trybek G J Clin Med. 2021; 10(10).

PMID: 34069560 PMC: 8160862. DOI: 10.3390/jcm10102197.


The Impact of Using Kinesio Tape on Non-Infectious Complications after Impacted Mandibular Third Molar Surgery.

Jaron A, Preuss O, Grzywacz E, Trybek G Int J Environ Res Public Health. 2021; 18(2).

PMID: 33419167 PMC: 7825547. DOI: 10.3390/ijerph18020399.


Reliability of the Linear Measurement (Contact) Method Compared with Stereophotogrammetry (Optical Scanning) for the Evaluation of Edema after Surgically Assisted Rapid Maxillary Expansion.

Kocer G, Sonmez S, Findik Y, Yazici T Healthcare (Basel). 2020; 8(1).

PMID: 32121496 PMC: 7151041. DOI: 10.3390/healthcare8010052.