MRI diffusion imaging is effective in measuring the diffusion tensor in brain, cardiac, liver, and spinal tissue. Diffusion tensor tomography MRI (DTT MRI) method is based on reconstructing the diffusion tensor field from measurements of projections of the tensor field. Projections are obtained by appropriate application of rotated diffusion gradients. In the present paper, the potential of a novel data acquisition scheme, PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction), is examined in combination with DTT MRI for its capability and sufficiency for diffusion imaging. An iterative reconstruction algorithm is used to reconstruct the diffusion tensor field from rotated diffusion weighted blades by appropriate rotated diffusion gradients. DTT MRI with PROPELLER data acquisition shows significant potential to reduce the number of weighted measurements, avoid ambiguity in reconstructing diffusion tensor parameters, increase signal-to-noise ratio, and decrease the influence of signal distortion.

Citing Articles

Diffusion Weighted Imaging Super-Resolution Algorithm for Highly Sparse Raw Data Sequences.

Malczewski K Sensors (Basel). 2023; 23(12).

PMID: 37420864 PMC: 10302017. DOI: 10.3390/s23125698.


Evaluation of apparent diffusion coefficient of two-dimensional BLADE turbo gradient- and spin-echo diffusion-weighted imaging with a breast phantom.

Ohki A, Sagawa H, Iima M, Kataoka M, Fushimi Y, Zhou K Radiol Phys Technol. 2023; 16(1):118-126.

PMID: 36596917 DOI: 10.1007/s12194-022-00694-y.


The ultrastructural and morphological characteristics of the anterior cruciate ligament of the pig: a study using 7.0-Tesla diffusion tensor imaging.

You T, Jiao F, Zhang W, Yang Q, Lu W, Luo Y J Int Med Res. 2022; 50(11):3000605221121954.

PMID: 36324250 PMC: 9634201. DOI: 10.1177/03000605221121954.


Tomography of dark-field scatter including single-exposure Moiré fringe analysis with X-ray biprism interferometry-A simulation study.

Tao W, Sung Y, Kim S, Huang Q, Gullberg G, Seo Y Med Phys. 2021; 48(10):6293-6311.

PMID: 34407202 PMC: 8855978. DOI: 10.1002/mp.15134.


Accelerated model-based quantitative diffusion MRI: A feasibility study for musculoskeletal application.

Hufken T, Arbogast J, Bracher A, Beer M, Neubauer H, Rasche V Z Med Phys. 2021; 32(2):240-247.

PMID: 34175164 PMC: 9948881. DOI: 10.1016/j.zemedi.2021.04.004.