» Articles » PMID: 14961745

Interdigitated Array Microelectrode-based Electrochemical Impedance Immunosensor for Detection of Escherichia Coli O157:H7

Overview
Journal Anal Chem
Specialty Chemistry
Date 2004 Feb 14
PMID 14961745
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

A label-free electrochemical impedance immunosensor for rapid detection of Escherichia coli O157:H7 was developed by immobilizing anti-E. coli antibodies onto an indium-tin oxide interdigitated array (IDA) microelectrode. Based on the general electronic equivalent model of an electrochemical cell and the behavior of the IDA microelectrode, an equivalent circuit, consisting of an ohmic resistor of the electrolyte between two electrodes and a double layer capacitor, an electron-transfer resistor, and a Warburg impedance around each electrode, was introduced for interpretation of the impedance components of the IDA microelectrode system. The results showed that the immobilization of antibodies and the binding of E. coli cells to the IDA microelectrode surface increased the electron-transfer resistance, which was directly measured with electrochemical impedance spectroscopy in the presence of [Fe(CN)(6)](3-/4-) as a redox probe. The electron-transfer resistance was correlated with the concentration of E. coli cells in a range from 4.36 x 10(5) to 4.36 x 10(8) cfu/mL with the detection limit of 10(6) cfu/mL.

Citing Articles

A Review on Microfluidics-Based Impedance Biosensors.

Chen Y, Huang C, Pai P, Seo J, Lei K Biosensors (Basel). 2023; 13(1).

PMID: 36671918 PMC: 9855525. DOI: 10.3390/bios13010083.


A New Biorecognition-Element-Free IDμE Sensor for the Identification and Quantification of .

Lin Y, Wu H, Van Hieu N, Chu P, Do T, Yao F Biosensors (Basel). 2022; 12(8).

PMID: 35892458 PMC: 9331394. DOI: 10.3390/bios12080561.


Recent Advancements in Electrochemical Biosensors for Monitoring the Water Quality.

Hui Y, Huang Z, Alahi M, Nag A, Feng S, Mukhopadhyay S Biosensors (Basel). 2022; 12(7).

PMID: 35884353 PMC: 9313366. DOI: 10.3390/bios12070551.


Early detection of bacteria using SPR imaging and event counting: experiments with and .

Boulade M, Morlay A, Piat F, Roupioz Y, Livache T, Charette P RSC Adv. 2022; 9(27):15554-15560.

PMID: 35514840 PMC: 9064316. DOI: 10.1039/c9ra01466g.


Cranberry Proanthocyanidins-PANI Nanocomposite for the Detection of Bacteria Associated with Urinary Tract Infections.

Urena-Saborio H, Udayan A, Alfaro-Viquez E, Madrigal-Carballo S, Reed J, Gunasekaran S Biosensors (Basel). 2021; 11(6).

PMID: 34205292 PMC: 8235105. DOI: 10.3390/bios11060199.