Abstract

As mechanical usage (MU) of a bone changes from complete disuse towards maximal vigor, the biologic mechanisms that can adapt it to its MU tend to react predictably. Acute disuse can increase BMU (Basic Multicellular Unit, the remodeling 'packet') creations but reduces how much bone they form, to increase bone loss next to marrow. Normal usage reduces those creations to normal and tends to equalize their resorption and formation; this conserves bone. In mild overloading, BMUs still conserve existing bone, while modeling drifts can begin adding to and/or reshaping it. Severe overloading can increase microdamage alarmingly, its repair by BMUs too, and can cause woven bone formation, anarchic resorption and a regional acceleratory phenomenon. Those ranges of MU vigor can define four 'windows'. An adapted window should apply to healthy, normally active adult mammals, and a mild overload window to healthy, normally active growing ammals. The biologic responses in the pathologic window could explain among other things some total joint and internal fixation failures, some pathologic fractures and some bone healing and sports medicine problems.

Citing Articles

Treatment of Chronic Haemophilic Synovitis with PRP: Clinical and Studies.

Caviglia H, Landro M, Oneto P, Cambiaggi G, Galatro G, Berni M Int J Mol Sci. 2024; 25(17).

PMID: 39273089 PMC: 11395128. DOI: 10.3390/ijms25179140.


Comparative biomechanics of all-on-4 and vertical implant placement in asymmetrical mandibular: a finite element study.

Sun X, Tang X, Cheng K, Xia Z, Liu Y, Yang F BMC Oral Health. 2024; 24(1):425.

PMID: 38582842 PMC: 10998417. DOI: 10.1186/s12903-024-04186-w.


Crestal and Subcrestal Placement of Morse Cone Implant-Abutment Connection Implants: An In Vitro Finite Element Analysis (FEA) Study.

Comuzzi L, Ceddia M, Di Pietro N, Inchingolo F, Inchingolo A, Romasco T Biomedicines. 2023; 11(11).

PMID: 38002077 PMC: 10669349. DOI: 10.3390/biomedicines11113077.


Regional Migratory Osteoporosis - A Rare Cause of Knee Pain (Case Report).

Moiyad S, Barui E, Wall C J Orthop Case Rep. 2023; 13(7):145-148.

PMID: 37521395 PMC: 10379256. DOI: 10.13107/jocr.2023.v13.i07.3788.


Biomechanical comparison of all-on-4 and all-on-5 implant-supported prostheses with alteration of anterior-posterior spread: a three-dimensional finite element analysis.

Sun X, Cheng K, Liu Y, Ke S, Zhang W, Wang L Front Bioeng Biotechnol. 2023; 11:1187504.

PMID: 37397958 PMC: 10313229. DOI: 10.3389/fbioe.2023.1187504.