» Articles » PMID: 14673451

A Biomechanical Comparison of Three Lower Extremity Tendons for Ligamentous Reconstruction About the Knee

Overview
Journal Arthroscopy
Specialty Orthopedics
Date 2003 Dec 16
PMID 14673451
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The purpose of this investigation was to evaluate 3 previously unreported allograft tendons for use in knee surgery. These are the doubled tibialis anterior (TA), doubled tibialis posterior (TP), and doubled peroneus longus (PL) tendons.

Type Of Study: A biomechanical evaluation of the properties of the TA, TP, and PL.

Methods: Sixteen fresh-frozen cadaveric lower limbs were used for testing. All specimens had the TA, TP, and PL tendons harvested. All specimens were tested in a custom-designed hydraulic testing machine using dry ice clamps. Each tendon was elongated at a rate of 1 mm/s. Load and displacement were recorded with an analog to digital interface board. Stiffness, modulus of elasticity, and stress and strain at failure were calculated.

Results: The average tested lengths of the TA, TP, and PL were 37 cm (range, 13-68 cm), 33 cm (range, 7-74 cm), and 42 cm (range, 17-69 cm), respectively. The average cross-sectional areas of the doubled TA, TP, and PL were 38 mm2, 48 mm2, and 37 mm2, respectively. The average failure loads for the doubled TA, TP, and PL tendons were 3,412 N, 3,391 N, and 2,483 N, respectively. The maximum stresses of the 3 tendons did not differ significantly (85-108 Mpa). The TA had the greatest stiffness (344 N/mm), followed by the TP (302 N/mm) and the PL (244 N/mm). Previous authors have documented the biomechanical strength of grafts for ACL reconstruction between 1,700 and 2,900 Newtons. The ultimate tensile strength and stiffness reported for the TA and TP grafts exceeded that for all previously reported grafts, including the doubled semitendinosus-gracilis.

Conclusions: The TA, TP, and PL tendons showed excellent biomechanical properties when compared with historical data evaluating other graft sources. The biomechanical properties observed for the TA, TP, and PL were noted in specimens despite an average age of 78.3 years.

Citing Articles

The Efficacy of Anterior Cruciate Ligament Reconstruction with Peroneus Longus Tendon and its Impact on Ankle Joint Function.

Zhang S, Cai G, Ge Z Orthop Surg. 2024; 16(6):1317-1326.

PMID: 38650179 PMC: 11144498. DOI: 10.1111/os.14060.


Biomechanical considerations for graft choice in anterior cruciate ligament reconstruction.

Banovetz M, Kennedy N, LaPrade R, Engebretsen L, Moatshe G Ann Jt. 2024; 8:17.

PMID: 38529237 PMC: 10929340. DOI: 10.21037/aoj-22-50.


The role of peroneus longus (PL) autograft in the reconstruction of anterior cruciate ligament (ACL): A comprehensive narrative review.

Viswanathan V, Iyengar K, Jain V J Clin Orthop Trauma. 2024; 49:102352.

PMID: 38356688 PMC: 10862405. DOI: 10.1016/j.jcot.2024.102352.


Anatomical and Biomechanical Characteristics of Peroneus Longus Tendon: Applications in Knee Cruciate Ligament Reconstruction Surgery.

Nguyen Hoang Q, Manh K Adv Orthop. 2023; 2023:2018363.

PMID: 37409219 PMC: 10319460. DOI: 10.1155/2023/2018363.


A Prospective, Double-Blind Evaluation of Anterior Cruciate Ligament Reconstruction With Tibialis Tendon Allograft: Donor Age Does Not Alter Outcomes.

Carter T, Norton A Arthrosc Sports Med Rehabil. 2023; 5(1):e267-e272.

PMID: 36866298 PMC: 9972004. DOI: 10.1016/j.asmr.2022.11.025.