Statistical Accuracy of a Moving Equivalent Dipole Method to Identify Sites of Origin of Cardiac Electrical Activation
Overview
Biophysics
Authors
Affiliations
While radio frequency (RF) catheter ablation (RCA) procedures for treating ventricular arrhythmias have evolved significantly over the past several years, the use of RCA has been limited to treating slow ventricular tachycardias (VTs). In this paper, we present preliminary results from computer and animal studies to evaluate the accuracy of an algorithm that uses the single equivalent moving dipole (SEMD) model in an infinite homogeneous volume conductor to guide the RF catheter to the site of origin of the arrhythmia. Our method involves measuring body surface electrocardiographic (ECG) signals generated by arrhythmic activity and by bipolar current pulses emanating from a catheter tip, and representing each of them by a SEMD model source at each instant of the cardiac cycle, thus enabling rapid repositioning of the catheter tip requiring only a few cycles of the arrhythmia. We found that the SEMD model accurately reproduced body surface ECG signals with a correlation coefficients > 0.95. We used a variety of methods to estimate the uncertainty of the SEMD parameters due to measurement noise and found that at the time when the arrhythmia is mostly localized during the cardiac cycle, the estimates of the uncertainty of the spatial SEMD parameters (from ECG signals) are between 1 and 3 mm. We used pacing data from spatially separated epicardial sites in a swine model as surrogates for focal ventricular arrhythmic sources and found that the spatial SEMD estimates of the two pacing sites agreed with both their physical separation and orientation with respect to each other. In conclusion, our algorithm to estimate the SEMD parameters from body surface ECG can potentially be a useful method for rapidly positioning the catheter tip to the arrhythmic focus during an RCA procedure.
Lu Z, Jiang D, Yang J Ann Noninvasive Electrocardiol. 2021; 26(6):e12879.
PMID: 34250679 PMC: 8588379. DOI: 10.1111/anec.12879.
Sohn K, Armoundas A Med Biol Eng Comput. 2016; 54(10):1611-9.
PMID: 26798056 PMC: 4958040. DOI: 10.1007/s11517-015-1437-x.
A method to noninvasively identify cardiac bioelectrical sources.
Sohn K, Lv W, Lee K, Galea A, Hirschman G, Barrett C Pacing Clin Electrophysiol. 2014; 37(8):1038-50.
PMID: 24645803 PMC: 4205085. DOI: 10.1111/pace.12380.
Lai D, Sun J, Li Y, He B Phys Med Biol. 2013; 58(11):3897-909.
PMID: 23681281 PMC: 3776132. DOI: 10.1088/0031-9155/58/11/3897.
Cardiac ablation catheter guidance by means of a single equivalent moving dipole inverse algorithm.
Lee K, Lv W, Ter-Ovanesyan E, Barley M, Voysey G, Galea A Pacing Clin Electrophysiol. 2013; 36(7):811-22.
PMID: 23448231 PMC: 4564260. DOI: 10.1111/pace.12114.