[Development of an Automated Patient-recognition Method for Digital Chest Radiographs Using Edge-enhanced Images]

Overview
Specialty Radiology
Date 2003 Dec 4
PMID 14646995
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

It is important that all images in a picture archiving and communication system (PACS) environment should be stored in the correct location, e.g., in the proper patient's folder. However, if patient information, such as identification number or patient name, has been entered incorrectly, the image may be stored in the wrong place. We are developing an automated patient recognition method for chest radiographs based on a template-matching technique to prevent such filing errors. To further improve the performance of our method, we investigated the usefulness of a new automated patient-recognition method based on a template-matching technique by using edge-enhanced and smoothed images. We found that the relationship between the correlation values obtained with and without the edge-enhancement technique tended to provide different criteria for identifying correct or incorrect patients. When we combined the two methods to distinguish the images by a rule-based method, 67.1% of wrongly identified patients in our database could be identified as wrongly identified, without any false warnings for correctly identified patients. We consider that this automated method for patient recognition based on edge-enhanced images would be useful in preventing "wrong" images from being stored in a PACS environment.

Citing Articles

Clinical application of biological fingerprints extracted from averaged chest radiographs and template-matching technique for preventing left-right flipping mistakes in chest radiography.

Sakai Y, Takahashi K, Shimizu Y, Ishibashi E, Kato T, Morishita J Radiol Phys Technol. 2019; 12(2):216-223.

PMID: 30784015 DOI: 10.1007/s12194-019-00504-y.


Development of a method of automated extraction of biological fingerprints from chest radiographs as preprocessing of patient recognition and identification.

Shimizu Y, Morishita J Radiol Phys Technol. 2017; 10(3):376-381.

PMID: 28452001 DOI: 10.1007/s12194-017-0400-y.


Evaluation of the usefulness of modified biological fingerprints in chest radiographs for patient recognition and identification.

Shimizu Y, Matsunobu Y, Morishita J Radiol Phys Technol. 2016; 9(2):240-4.

PMID: 27132238 DOI: 10.1007/s12194-016-0355-4.


Computerized image-searching method for finding correct patients for misfiled chest radiographs in a PACS server by use of biological fingerprints.

Toge R, Morishita J, Sasaki Y, Doi K Radiol Phys Technol. 2013; 6(2):437-43.

PMID: 23771325 DOI: 10.1007/s12194-013-0221-6.


Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy.

Arimura H, Itano W, Shioyama Y, Matsushita N, Magome T, Yoshitake T J Radiat Res. 2012; 53(6):961-72.

PMID: 22843375 PMC: 3483845. DOI: 10.1093/jrr/rrs043.