» Articles » PMID: 14643602

Hydroxyapatite/poly(epsilon-caprolactone) Composite Coatings on Hydroxyapatite Porous Bone Scaffold for Drug Delivery

Overview
Journal Biomaterials
Date 2003 Dec 4
PMID 14643602
Citations 77
Authors
Affiliations
Soon will be listed here.
Abstract

Hydroxyapatite (HA) porous scaffold was coated with HA and polycaprolactone (PCL) composites, and antibiotic drug tetracycline hydrochloride was entrapped within the coating layer. The HA scaffold obtained by a polymeric reticulate method, possessed high porosity ( approximately 87%) and controlled pore size (150-200 microm). Such a well-developed porous structure facilitated usage in a drug delivery system due to its high surface area and blood circulation efficiency. The PCL polymer, as a coating component, was used to improve the brittleness and low strength of the HA scaffold, as well to effectively entrap the drug. To improve the osteoconductivity and bioactivity of the coating layer, HA powder was hybridized with PCL solution to make the HA-PCL composite coating. With alteration in the coating concentration and HA/PCL ratio, the morphology, mechanical properties, and biodegradation behavior were investigated. Increasing the concentration rendered the stems thicker and some pores to be clogged; as well increasing the HA/PCL ratio made the coating surface be rough due to the large amount of HA particles. However, for all concentrations and compositions, uniform coatings were formed, i.e., with the HA particles being dispersed homogeneously in the PCL sheet. With the composite coating, the mechanical properties, such as compressive strength and elastic modulus were improved by several orders of magnitude. These improvements were more significant with thicker coatings, while little difference was observed with the HA/PCL ratio. The in vitro biodegradation of the composite coatings in the phosphate buffered saline solution increased linearly with incubation time and the rate differed with the coating concentration and the HA/PCL ratio; the higher concentration and HA amount caused the increased biodegradation. At short period (<2 h), about 20-30% drug was released especially due to free drug at the coating surface. However, the release rate was sustained for prolonged periods and was highly dependent on the degree of coating dissolution, suggesting the possibility of a controlled drug release in the porous scaffold with HA+PCL coating.

Citing Articles

Evaluation of calcium phosphate-coated polycaprolactone/graphene oxide scaffold with macro- and microporous structure for bone tissue engineering.

Kim S, Kim N, Park S, Choi J, Song Y, Tumursukh N In Vitro Model. 2025; 1(3):261-272.

PMID: 39871868 PMC: 11756476. DOI: 10.1007/s44164-022-00026-9.


Fabrication of biocidal materials based on the molecular interactions of tetracycline and quercetin with hydroxyapatite via and In vitro approaches.

Isakova A, Kutyrev M, Kudasheva A, Rogacheva E, Kraeva L, Shityakov S Heliyon. 2025; 11(1):e41064.

PMID: 39758386 PMC: 11699380. DOI: 10.1016/j.heliyon.2024.e41064.


Influence of Heat Treatment of Nitinol Wire on the Properties of Nitinol/Hybrid Layer for Ibuprofen Release.

Mroczka R, Slodkowska A, Kubacki J Molecules. 2024; 29(21).

PMID: 39519841 PMC: 11547518. DOI: 10.3390/molecules29215200.


Biodegradable composites with antibiotics and growth factors for dual release kinetics.

Seidenstuecker M, Hess J, Baghnavi A, Schmal H, Voigt D, Mayr H J Mater Sci Mater Med. 2024; 35(1):40.

PMID: 39073605 PMC: 11286658. DOI: 10.1007/s10856-024-06809-8.


Fabrication of k-Carrageenan/Alginate/Carboxymethyl Cellulose basedScaffolds via 3D Printing for Potential Biomedical Applications.

Stavarache C, Ghebaur A, Serafim A, Vlasceanu G, Vasile E, Garea S Polymers (Basel). 2024; 16(11).

PMID: 38891538 PMC: 11174997. DOI: 10.3390/polym16111592.