» Articles » PMID: 14618441

Pencil-beam Versus Fan-beam Dual-energy X-ray Absorptiometry Comparisons Across Four Systems: Appendicular Lean Soft Tissue

Overview
Journal Acta Diabetol
Specialty Endocrinology
Date 2003 Nov 18
PMID 14618441
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Dual-energy X-ray absorptiometry (DXA) provides an important opportunity for estimating total body skeletal muscle (SM) mass from DXA-measured appendicular lean soft tissue (ALST). A DXA SM prediction model was developed with magnetic resonance imaging as the reference and ALST (i. e., sum of arm plus leg lean soft tissue) as a main predictor variable. In the present study we examined whether ALST estimates are comparable across systems (i. e., penciland fan-beam) and manufacturers. Pencil-beam systems (Lunar DPX and DPX-L) are usually considered more accurate but slower than fan-beam systems (Lunar Prodigy and Hologic Delphi A). In this study we compared ALST estimates in 35 healthy adults across these four systems. The methods gave similar group mean (+/-SD) values and were highly intercorrelated. There was no significant bias detected across the four systems. ALST estimates from the evaluated DXA systems are comparable and thus appear interchangeable as methods for quantifying total body SM in vivo.

Citing Articles

Study Design and Rationale for the Phase 3 Clinical Development Program of Enobosarm, a Selective Androgen Receptor Modulator, for the Prevention and Treatment of Muscle Wasting in Cancer Patients (POWER Trials).

Crawford J, Prado C, Johnston M, Gralla R, Taylor R, Hancock M Curr Oncol Rep. 2016; 18(6):37.

PMID: 27138015 PMC: 4853438. DOI: 10.1007/s11912-016-0522-0.


Lumbar spine and total-body dual-energy X-ray absorptiometry in children with severe neurological impairment and intellectual disability: a pilot study of artefacts and disrupting factors.

Mergler S, Rieken R, Tibboel D, Evenhuis H, van Rijn R, Penning C Pediatr Radiol. 2012; 42(5):574-83.

PMID: 22252145 PMC: 3337401. DOI: 10.1007/s00247-011-2307-9.


Look before you leap: on the issue of muscle mass assessment by dual-energy X-ray absorptiometry (reply to Jordan Robert Moon comments).

Calbet J, Perez-Gomez J, Vicente-Rodriguez G, Ara I, Olmedillas H, Chavarren J Eur J Appl Physiol. 2008; 104(3):587-8.

PMID: 18607622 DOI: 10.1007/s00421-008-0774-y.


Total-body skeletal muscle mass: estimation by dual-energy X-ray absorptiometry in children and adolescents.

Kim J, Shen W, Gallagher D, Jones Jr A, Wang Z, Wang J Am J Clin Nutr. 2006; 84(5):1014-20.

PMID: 17093152 PMC: 2747777. DOI: 10.1093/ajcn/84.5.1014.


Pediatric in vivo cross-calibration between the GE Lunar Prodigy and DPX-L bone densitometers.

Crabtree N, Shaw N, Boivin C, Oldroyd B, Truscott J Osteoporos Int. 2005; 16(12):2157-67.

PMID: 16234997 DOI: 10.1007/s00198-005-2021-2.