Abstract

Background: In the US, Quality Indicators (QI's) profiling and comparing the performance of hospitals, health plans, nursing homes and physicians are routinely published for consumer review. We report the results of the largest study of inter-rater reliability done on nursing home assessments which generate the data used to derive publicly reported nursing home quality indicators.

Methods: We sampled nursing homes in 6 states, selecting up to 30 residents per facility who were observed and assessed by research nurses on 100 clinical assessment elements contained in the Minimum Data Set (MDS) and compared these with the most recent assessment in the record done by facility nurses. Kappa statistics were generated for all data items and derived for 22 QI's over the entire sample and for each facility. Finally, facilities with many QI's with poor Kappa levels were compared to those with many QI's with excellent Kappa levels on selected characteristics.

Results: A total of 462 facilities in 6 states were approached and 219 agreed to participate, yielding a response rate of 47.4%. A total of 5758 residents were included in the inter-rater reliability analyses, around 27.5 per facility. Patients resembled the traditional nursing home resident, only 43.9% were continent of urine and only 25.2% were rated as likely to be discharged within the next 30 days. Results of resident level comparative analyses reveal high inter-rater reliability levels (most items >.75). Using the research nurses as the "gold standard", we compared composite quality indicators based on their ratings with those based on facility nurses. All but two QI's have adequate Kappa levels and 4 QI's have average Kappa values in excess of.80. We found that 16% of participating facilities performed poorly (Kappa <.4) on more than 6 of the 22 QI's while 18% of facilities performed well (Kappa >.75) on 12 or more QI's. No facility characteristics were related to reliability of the data on which Qis are based.

Conclusion: While a few QI's being used for public reporting have limited reliability as measured in US nursing homes today, the vast majority of QI's are measured reliably across the majority of nursing facilities. Although information about the average facility is reliable, how the public can identify those facilities whose data can be trusted and whose cannot remains a challenge.

Citing Articles

Nursing-sensitive quality indicators for quality improvement in Norwegian nursing homes - a modified Delphi study.

Tevik K, Helvik A, Stensvik G, Nordberg M, Nakrem S BMC Health Serv Res. 2023; 23(1):1068.

PMID: 37803376 PMC: 10557356. DOI: 10.1186/s12913-023-10088-4.


Accuracy of infection reporting in US nursing home ratings.

Chen Z, Gleason L, Konetzka R, Sanghavi P Health Serv Res. 2023; 58(5):1109-1118.

PMID: 37348846 PMC: 10480086. DOI: 10.1111/1475-6773.14195.


Underreporting of Quality Measures and Associated Facility Characteristics and Racial Disparities in US Nursing Home Ratings.

Sanghavi P, Chen Z JAMA Netw Open. 2023; 6(5):e2314822.

PMID: 37219904 PMC: 10208148. DOI: 10.1001/jamanetworkopen.2023.14822.


Evidence for publicly reported quality indicators in residential long-term care: a systematic review.

Osinska M, Favez L, Zuniga F BMC Health Serv Res. 2022; 22(1):1408.

PMID: 36424603 PMC: 9686098. DOI: 10.1186/s12913-022-08804-7.


The design and conduct of a pragmatic cluster randomized trial of an advance care planning program for nursing home residents with dementia.

Hickman S, Mitchell S, Hanson L, Tu W, Stump T, Unroe K Clin Trials. 2022; 19(6):623-635.

PMID: 35815777 PMC: 9691516. DOI: 10.1177/17407745221108992.


References
1.
BLACKMAN N, Koval J . Interval estimation for Cohen's kappa as a measure of agreement. Stat Med. 2000; 19(5):723-41. DOI: 10.1002/(sici)1097-0258(20000315)19:5<723::aid-sim379>3.0.co;2-a. View

2.
Harrington C . Developing public information on nursing home quality. J Aging Soc Policy. 1990; 3(1-2):127-46. DOI: 10.1300/J031v03n01_10. View

3.
Ahronheim J, Mulvihill M, Sieger C, Park P, Fries B . State practice variations in the use of tube feeding for nursing home residents with severe cognitive impairment. J Am Geriatr Soc. 2001; 49(2):148-52. DOI: 10.1046/j.1532-5415.2001.49035.x. View

4.
Berlowitz D, Brandeis G, Morris J, Ash A, Anderson J, Kader B . Deriving a risk-adjustment model for pressure ulcer development using the Minimum Data Set. J Am Geriatr Soc. 2001; 49(7):866-71. DOI: 10.1046/j.1532-5415.2001.49175.x. View

5.
Scinto J, Galusha D, Krumholz H, Meehan T . The case for comprehensive quality indicator reliability assessment. J Clin Epidemiol. 2001; 54(11):1103-11. DOI: 10.1016/s0895-4356(01)00381-x. View