» Articles » PMID: 14588296

Influence of Bone Mineral Density on Pedicle Screw Fixation: a Study of Pedicle Screw Fixation Augmenting Posterior Lumbar Interbody Fusion in Elderly Patients

Overview
Journal Spine J
Specialty Orthopedics
Date 2003 Nov 1
PMID 14588296
Citations 68
Authors
Affiliations
Soon will be listed here.
Abstract

Background Context: Some biomechanical studies have demonstrated that bone mineral density of the lumbar spine (BMD) affects the stability of pedicle screws in vitro.

Purpose: To investigate influence of BMD on loosening and related failure of pedicle screws in vivo.

Study Design/setting: A clinical study of 52 patients who underwent pedicle screw fixation augmenting posterior lumbar interbody fusion (PLIF).

Patient Sample: There were 13 men and 39 women, with an average age of 63 years (range, 45-76 years) at the time of operation. The mean follow-up period was 2.8 years (range, 2-6 years).

Outcome Measures: Relationship between BMD, screw loosening, and its related failures were statistically analyzed.

Methods: BMD was measured by the dual energy X-ray absorptiometry (DEXA) method. Radiographic assessments were done by the first author and independently by another orthopedist who was not informed of the values of BMD.

Results: The mean BMD of all patients was 0.879 +/- 0.215 (mean +/- S.D.) g/cm2. The mean BMD in patients with and without screw loosening was 0.720 +/- 0.078 g/cm2 (n=11) and 0.922 +/- 0.221 g/cm2 (n=41). There was a significant difference between the mean BMD of patients with and without screw loosening (P<.01). The mean BMD of patients with "union," "nonunion" and "undetermined union" was 0.934 +/- 0.210 g/cm2 (n=40), 0.674 +/- 0.104 g/cm2 (n=4) and 0.710 +/- 0.116 g/cm2 (n=8), respectively. The mean BMD of patients with "union" was significantly greater than those with "nonunion" and "undetermined union" (P<.05).

Conclusion: It could be concluded that BMD has a close relation with the stability of pedicle screws in vivo, and BMD value below 0.674 +/- 0.104 g/cm2 suggests a potential increased risk of "nonunion" when pedicle screw fixation is performed in conjunction with PLIF.

Citing Articles

The MRI-based vertebral bone quality score is a predictor of pedicle screw loosening following instrumented posterior lumbar fusion.

Hu Y, Chou J, Yeh Y, Hsieh M, Tsai T, Chen W Sci Rep. 2025; 15(1):1696.

PMID: 39799229 PMC: 11724917. DOI: 10.1038/s41598-025-85625-8.


Bone density as a risk of early loss of correction after percutaneous posterior spinal fixation for traumatic thoracolumbar fracture: a study on the usefulness of Hounsfield unit values on computed tomography scan.

Akabane T, Suzuki T, Konno Y, Sagae H, Sugita M, Hasegawa H Eur Spine J. 2024; 34(2):498-505.

PMID: 39368028 DOI: 10.1007/s00586-024-08508-y.


An Extended Follow-up of Spinal Instrumentation Rescue with Cement Augmentation.

Polinelli F, Pileggi M, Cabrilo I, Commodaro C, Van Kuijk S, Cardia A AJNR Am J Neuroradiol. 2024; 45(11):1805-1810.

PMID: 38914434 PMC: 11543086. DOI: 10.3174/ajnr.A8394.


Risk analysis index predicts mortality and non-home discharge following posterior lumbar interbody fusion: a nationwide inpatient sample analysis of 429,380 patients (2019-2020).

Covell M, Rumalla K, Bhalla S, Bowers C Eur Spine J. 2024; 33(9):3484-3491.

PMID: 38902536 DOI: 10.1007/s00586-024-08373-9.


Impact of bone density and integrated screw configuration on standalone anterior lumbar interbody construct strength.

Dies R, Manuel J, Zhang A, Mody M, Lee S, Root M N Am Spine Soc J. 2024; 18:100325.

PMID: 38812953 PMC: 11133976. DOI: 10.1016/j.xnsj.2024.100325.