» Articles » PMID: 14523950

Neurobehavioral Effects Among Subjects Exposed to High Static and Gradient Magnetic Fields from a 1.5 Tesla Magnetic Resonance Imaging System--a Case-crossover Pilot Study

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2003 Oct 3
PMID 14523950
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral test battery were compared in four 1-hr sessions with and without exposure to magnetic fields, and with and without additional movements. Adverse effects were found for hand coordination (-4%, P < 0.05; Pursuit Aiming II) and near visual contrast sensitivity (-16% and -15%, P < 0.10; Vistech 6000). The results from the remaining tests were inconclusive due to a strong learning effect. No additional effect from gradient fields was detected. The results indicate that working near a 1.5 Tesla MRI system may lead to neurobehavioral effects. Further research is recommended, especially in members of operating teams using interactive MRI systems.

Citing Articles

Behavioral and neural responses to high-strength magnetic fields are reduced in otolith mutant mice.

Cote J, Hood A, Kwon B, Smith J, Houpt T Am J Physiol Regul Integr Comp Physiol. 2023; 325(2):R181-R192.

PMID: 37306398 PMC: 10393321. DOI: 10.1152/ajpregu.00317.2022.


Subjective Symptoms in Magnetic Resonance Imaging Personnel: A Multi-Center Study in Italy.

Bravo G, Modenese A, Arcangeli G, Bertoldi C, Camisa V, Corona G Front Public Health. 2021; 9:699675.

PMID: 34692618 PMC: 8530375. DOI: 10.3389/fpubh.2021.699675.


Effect of Static Magnetic Field of Electric Vehicles on Driving Performance and on Neuro-Psychological Cognitive Functions.

He Y, Sun W, Leung P, Chow Y Int J Environ Res Public Health. 2019; 16(18).

PMID: 31547412 PMC: 6765815. DOI: 10.3390/ijerph16183382.


Safety of exposure to high static magnetic fields (2 T-12 T): a study on mice.

Wang S, Luo J, Lv H, Zhang Z, Yang J, Dong D Eur Radiol. 2019; 29(11):6029-6037.

PMID: 31115627 DOI: 10.1007/s00330-019-06256-y.


Acute vertigo in an anesthesia provider during exposure to a 3T MRI scanner.

Gorlin A, Hoxworth J, Pavlicek W, Thunberg C, Seamans D Med Devices (Auckl). 2015; 8:161-6.