Antibodies to Silicone Elastomers and Reactions to Ventriculoperitoneal Shunts

Overview
Journal Lancet
Publisher Elsevier
Specialty General Medicine
Date 1992 Aug 29
PMID 1354277
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

Silicone elastomers used to make medical implants and prostheses are generally believed to be biologically inert. However, we have seen two patients who showed severe, apparently immunemediated, reactions to ventriculoperitoneal (VP) shunts. We used an enzyme-linked immunosorbent assay in which Silastic tubing served as the solid-phase antigen to test serum from the two patients, five other VP shunt patients without inflammatory reactions, and nine healthy adults. IgG binding to Silastic tubing was consistently higher in the two patients than in the healthy or patient controls. The IgG seemed to be binding specifically, since IgG Fab fragments also bound to the tubing, and preincubation of serum with Silastic or silylated proteins removed most of the activity. These findings show that specific immune reactivity to elastomers of polydimethylsiloxane can develop in human beings.

Citing Articles

Silicone allergy manifestation in pediatric ventriculoperitoneal shunting: navigating diagnostic challenges and customizing therapeutic approaches. Illustrative case.

Riffo C, Rolack N, Mohor D, Berkhoff A, Monnier E, Antonio L J Neurosurg Case Lessons. 2024; 8(13).

PMID: 39312808 PMC: 11418643. DOI: 10.3171/CASE2474.


Autoimmune/inflammatory syndrome induced by adjuvants in a woman with Hashimoto thyroiditis and familial autoimmunity-a case report and literature review.

Plavsic A, Arandjelovic S, Dimitrijevic M, Kusic N, Tomic Spiric V, Popovic B Front Immunol. 2023; 14:1139603.

PMID: 37287963 PMC: 10242122. DOI: 10.3389/fimmu.2023.1139603.


Measuring Platinum Levels in Hair in Women with Silicone Breast Implants and Systemic Symptoms.

Spit K, Azahaf S, de Blok C, Nanayakkara P Plast Reconstr Surg Glob Open. 2022; 10(6):e4373.

PMID: 35702355 PMC: 9187172. DOI: 10.1097/GOX.0000000000004373.


Catastrophic Embolism Following Cosmetic Injection of Autologous Fat: Are Silicone-Treated Syringes the Only Suspects on the Crime Scene?.

Vojdani A, Shoenfeld Y Front Surg. 2022; 9:867994.

PMID: 35615656 PMC: 9124850. DOI: 10.3389/fsurg.2022.867994.


Eosinophilic Reaction at the Time of Catheter Insertion Predicts Survival in Patients Initiating Peritoneal Dialysis.

Uchiyama K, Washida N, Kusahana E, Nakayama T, Morimoto K, Itoh H Blood Purif. 2021; 51(4):355-364.

PMID: 34284388 PMC: 9116602. DOI: 10.1159/000517349.