» Articles » PMID: 1312785

Recovery from Exercise-induced Desaturation in the Quadriceps Muscles of Elite Competitive Rowers

Overview
Journal Am J Physiol
Specialty Physiology
Date 1992 Mar 1
PMID 1312785
Citations 109
Authors
Affiliations
Soon will be listed here.
Abstract

A simple muscle tissue spectrophotometer is adapted to measure the recovery time (TR) for hemoglobin/myoglobin (Hb/Mb) desaturation in the capillary bed of exercising muscle, termed a deoxygenation meter. The use of the instrument for measuring the extent of deoxygenation is presented, but the use of TR avoids difficulties of quantifying Hb/Mb saturation changes. The TR reflects the balance of oxygen delivery and oxygen demand in the localized muscles of the quadriceps following work near maximum voluntary contraction (MVC) in elite male and female rowers (a total of 22) on two occasions, 1 yr apart. TR ranged from 10 to 80 s and was interpreted as a measure of the time for repayment of oxygen and energy deficits accumulated during intense exercise by tissue respiration under ADP control. The Hb/Mb resaturation times provide a noninvasive localized indication of the degree of O2 delivery stress as evoked by rowing ergometry and may provide directions for localized muscle power output improvement for particular individuals in rowing competitions.

Citing Articles

Respiratory and locomotor muscle blood flow measurements using near-infrared spectroscopy and indocyanine green dye in health and disease.

Megaritis D, Echevarria C, Vogiatzis I Chron Respir Dis. 2024; 21:14799731241246802.

PMID: 38590151 PMC: 11003331. DOI: 10.1177/14799731241246802.


Differential impact of heat and hypoxia on dynamic oxygen uptake and deoxyhemoglobin parameters during incremental exhaustive exercise.

Geng Z, Wang J, Cao G, Tan C, Li L, Qiu J Front Physiol. 2024; 14:1247659.

PMID: 38260100 PMC: 10801013. DOI: 10.3389/fphys.2023.1247659.


A Wireless Multi-Layered EMG/MMG/NIRS Sensor for Muscular Activity Evaluation.

Kimoto A, Fujiyama H, Machida M Sensors (Basel). 2023; 23(3).

PMID: 36772579 PMC: 9919115. DOI: 10.3390/s23031539.


Evaluation of Muscle Oxygen Dynamics in Children's Gait and Its Relationship with the Physiological Cost Index.

Shirai Y, Ito T, Ito Y, Matsunaga N, Noritake K, Ochi N Healthcare (Basel). 2023; 11(2).

PMID: 36673589 PMC: 9858938. DOI: 10.3390/healthcare11020221.


Muscle Oxygenation Measured with Near-Infrared Spectroscopy Following Different Intermittent Training Protocols in a World-Class Kayaker-A Case Study.

Paulauskas R, Nekriosius R, Dadeliene R, Sousa A, Figueira B Sensors (Basel). 2022; 22(21).

PMID: 36365935 PMC: 9653646. DOI: 10.3390/s22218238.