» Articles » PMID: 12970908

Optical Properties of Human Normal Small Intestine Tissue Determined by Kubelka-Munk Method in Vitro

Overview
Specialty Gastroenterology
Date 2003 Sep 13
PMID 12970908
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To study the optical properties of human normal small intestine tissue at 476.5 nm, 488 nm, 496.5 nm, 514.5 nm, 532 nm, 808 nm wavelengths of laser irradiation.

Methods: A double-integrating-sphere system, the basic principle of measuring technology of light radiation, and an optical model of biological tissues were used in the study.

Results: The results of measurement showed that there were no significant differences in the absorption coefficients of human normal small intestine tissue at 476.5 nm, 488 nm, 496.5 nm laser in the Kubelka-Munk two-flux model (P>0.05). The absorption coefficients of the tissue at 514.5 nm, 532 nm, 808 nm laser irradiation were obviously increased with the decrease of these wavelengths. The scattering coefficients of the tissue at 476.5 nm, 488 nm, 496.5 nm laser irradiation were increased with the decrease of these wavelengths. The scattering coefficients at 496.5 nm, 514.5 nm, 532 nm laser irradiation were obviously increased with the increase of these wavelengths. The scattering coefficient of the tissue at 532 nm laser irradiation was bigger than that at 808 nm. There were no significant differences in the total attenuation coefficient of the tissue at 476.5 nm and 488 nm laser irradiation (P>0.05). The total attenuation coefficient of the tissue at 488 nm, 496.5 nm, 514.5 nm, 532 nm, 808 nm laser irradiation was obviously increased with the decrease of these wavelengths, and their effective attenuation coefficient revealed the same trend. There were no significant differences among the forward scattered photon fluxe, backward scattered photon fluxe, and total scattered photon fluxe of the tissue at 476.5 nm, 488 nm, 496.5 nm laser irradiation. They were all obviously increased with attenuation of tissue thickness. The attenuations of forward and backward scattered photon fluxes, and the total scattered photon fluxe of the tissue at 514.5 nm laser irradiation were slower than those at 476.5 nm, 488 nm, 496.5 nm laser irradiation respectively. The attenuations of forward and backward scattered photon fluxes, and total scattered photon fluxes at 532 nm laser irradiation were obviously slower than those at 476.5 nm, 488 nm, 496.5 nm, 514.5 nm laser irradiation. The attenuations of forward and backward scattered photon fluxes, and total scattered photon fluxe at 808 nm laser irradiation were all obviously slower than those at 476.5 nm, 488 nm, 496.5 nm, 514.5 nm, 532 nm laser irradiation respectively.

Conclusion: There are significant differences in optical parameters of human normal small intestine tissue in the Kubelka-Munk two-flux model at six different wavelengths of laser radiation. The results would provide a new method of information analysis for clinical diagnosis.

Citing Articles

Optical Characterization of Biological Tissues Based on Fluorescence, Absorption, and Scattering Properties.

Hamdy O, Abdel-Salam Z, Abdel-Harith M Diagnostics (Basel). 2022; 12(11).

PMID: 36428905 PMC: 9689259. DOI: 10.3390/diagnostics12112846.


Photothermally-Heated Superparamagnetic Polymeric Nanocomposite Implants for Interstitial Thermotherapy.

Yeboah I, Hatekah S, Yaya A, Kan-Dapaah K Nanomaterials (Basel). 2022; 12(6.

PMID: 35335769 PMC: 8950572. DOI: 10.3390/nano12060955.


Variations in tissue optical parameters with the incident power of an infrared laser.

Hamdy O, Mohammed H PLoS One. 2022; 17(1):e0263164.

PMID: 35100314 PMC: 8803203. DOI: 10.1371/journal.pone.0263164.


A Method for Medical Diagnosis Based on Optical Fluence Rate Distribution at Tissue Surface.

Hamdy O, El-Azab J, Al-Saeed T, Hassan M, Solouma N Materials (Basel). 2017; 10(9).

PMID: 28930158 PMC: 5615757. DOI: 10.3390/ma10091104.


Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study.

Alexandrakis G, Rannou F, Chatziioannou A Phys Med Biol. 2005; 50(17):4225-41.

PMID: 16177541 PMC: 1317109. DOI: 10.1088/0031-9155/50/17/021.

References
1.
Graaff R, Aarnoudse J, de Mul F, Jentink H . Light propagation parameters for anisotropically scattering media based on a rigorous solution of the transport equation. Appl Opt. 2010; 28(12):2273-9. DOI: 10.1364/AO.28.002273. View

2.
Pickering J, Prahl S, van Wieringen N, Beek J, Sterenborg H, van Gemert M . Double-integrating-sphere system for measuring the optical properties of tissue. Appl Opt. 2010; 32(4):399-410. DOI: 10.1364/AO.32.000399. View

3.
Gorti S, Tone H, Imokawa G . Triangulation method for determining capillary blood flow and physical characteristics of the skin. Appl Opt. 2008; 38(22):4914-29. DOI: 10.1364/ao.38.004914. View

4.
Vogel A, Dlugos C, Nuffer R, Birngruber R . Optical properties of human sclera, and their consequences for transscleral laser applications. Lasers Surg Med. 1991; 11(4):331-40. DOI: 10.1002/lsm.1900110404. View

5.
Ritz J, Roggan A, Isbert C, Muller G, Buhr H, Germer C . Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm. Lasers Surg Med. 2001; 29(3):205-12. DOI: 10.1002/lsm.1134. View