» Articles » PMID: 1297013

New Signal Processing Techniques for the Decomposition of EMG Signals

Overview
Publisher Springer
Date 1992 Nov 1
PMID 1297013
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

This paper relates to the use of knowledge-based signal processing techniques in the decomposition of EMG signals. The aim of the research is to automatically decompose EMG signals recorded at force levels up to 20 per cent maximum voluntary contraction (MVC) into their constituent motor unit action potentials (MUAPS), and to display the MUAP shapes and firing times for the clinician. This requires the classification of nonoverlapping MUAPs and superimposed waveforms formed from overlapping MUAPs in the signal. Nonoverlapping MUAPs are classified using a statistical pattern-recognition method. The decomposition of superimposed waveforms uses a combination of procedural and knowledge-based methods. The decomposition method was tested on real and simulated EMG data recorded at force levels up to 20 per cent MVC. The different EMG signals contained up to six motor units (MUs). The new decomposition program classifies the total number of MUAP firings in an EMG signal with an accuracy always greater than 95 per cent. The decomposition program takes about 15s to classify all nonoverlapping MUAPs in EMG signal of length 1.0s and, on average, an extra 9s to classify each superimposed waveform.

Citing Articles

Comparative Analysis of Wavelet-based Feature Extraction for Intramuscular EMG Signal Decomposition.

Ghofrani Jahromi M, Parsaei H, Zamani A, Dehbozorgi M J Biomed Phys Eng. 2018; 7(4):365-378.

PMID: 29392120 PMC: 5758715.


A Novel Framework Based on FastICA for High Density Surface EMG Decomposition.

Chen M, Zhou P IEEE Trans Neural Syst Rehabil Eng. 2015; 24(1):117-27.

PMID: 25775496 PMC: 4567540. DOI: 10.1109/TNSRE.2015.2412038.


Effect of multiscale PCA de-noising on EMG signal classification for diagnosis of neuromuscular disorders.

Gokgoz E, Subasi A J Med Syst. 2014; 38(4):31.

PMID: 24696395 DOI: 10.1007/s10916-014-0031-3.


Validating motor unit firing patterns extracted by EMG signal decomposition.

Parsaei H, Nezhad F, Stashuk D, Hamilton-Wright A Med Biol Eng Comput. 2010; 49(6):649-58.

PMID: 21042949 DOI: 10.1007/s11517-010-0703-1.


Decomposition of indwelling EMG signals.

Nawab S, Wotiz R, De Luca C J Appl Physiol (1985). 2008; 105(2):700-10.

PMID: 18483170 PMC: 2519944. DOI: 10.1152/japplphysiol.00170.2007.


References
1.
McGill K, Cummins K, Dorfman L . Automatic decomposition of the clinical electromyogram. IEEE Trans Biomed Eng. 1985; 32(7):470-7. DOI: 10.1109/TBME.1985.325562. View

2.
Hunter J . MAXIMAL DECOMPOSITION: AN ALTERNATIVE TO FACTOR ANALYSIS. Multivariate Behav Res. 2016; 7(2):243-68. DOI: 10.1207/s15327906mbr0702_8. View

3.
Bhullar H, Loudon G, Fothergill J, Jones N . Selective noninvasive electrode to study myoelectric signals. Med Biol Eng Comput. 1990; 28(6):581-6. DOI: 10.1007/BF02442611. View

4.
Mambrito B, De Luca C . A technique for the detection, decomposition and analysis of the EMG signal. Electroencephalogr Clin Neurophysiol. 1984; 58(2):175-88. DOI: 10.1016/0013-4694(84)90031-2. View

5.
Gerber A, Studer R, De Figueiredo R, Moschytz G . A new framework and computer program for quantitative EMG signal analysis. IEEE Trans Biomed Eng. 1984; 31(12):857-63. DOI: 10.1109/TBME.1984.325248. View