Development and Clinical Evaluation of an Internally Controlled, Single-tube Multiplex Real-time PCR Assay for Detection of Legionella Pneumophila and Other Legionella Species

Overview
Specialty Microbiology
Date 2003 Sep 6
PMID 12958219
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

A multiplex real-time PCR assay for detection of Legionella pneumophila and Legionella spp. and including an internal control was designed. Legionella species, L. pneumophila, and the internal control were detected simultaneously by probes labeled with 6-carboxy-fluorescein, hexachlorofluorescein, and indodicarbocyanine, respectively. Therefore, no postamplification analysis was required in order to distinguish the targets. The sensitivity of both assays was 2.5 CFU/ml, and from analysis of 10 culture-positive and 74 culture-negative samples from patients investigated for legionellosis, 100% agreement was observed by both assays in comparison to culture. Four additional positives were found by the multiplex real-time PCR assay in the Legionella culture-negative samples.

Citing Articles

Risk assessment and quantitative measurement along with monitoring of in hospital water sources.

Bavari S, Mirkalantari S, Masjedian Jazi F, Darban-Sarokhalil D, Golnari Marani B New Microbes New Infect. 2022; 45:100948.

PMID: 35399198 PMC: 8984627. DOI: 10.1016/j.nmni.2021.100948.


Evaluation of the Genmark ePlex® and QIAstat-Dx® respiratory pathogen panels in detecting bacterial targets in lower respiratory tract specimens.

van Asten S, Boers S, de Groot J, Schuurman R, Claas E BMC Microbiol. 2021; 21(1):236.

PMID: 34445973 PMC: 8390116. DOI: 10.1186/s12866-021-02289-w.


Evaluation of MALDI-TOF Mass Spectrometry in Diagnostic and Environmental Surveillance of Species: A Comparison With Culture and -Gene Sequencing Technique.

Pascale M, Mazzotta M, Salaris S, Girolamini L, Grottola A, Simone M Front Microbiol. 2021; 11:589369.

PMID: 33384668 PMC: 7771186. DOI: 10.3389/fmicb.2020.589369.


Novel use of culturomics to identify the microbiota in hospital sink drains with and without persistent VIM-positive Pseudomonas aeruginosa.

Pirzadian J, Harteveld S, Ramdutt S, van Wamel W, Klaassen C, Vos M Sci Rep. 2020; 10(1):17052.

PMID: 33051501 PMC: 7554030. DOI: 10.1038/s41598-020-73650-8.


Urinary antigene and PCR can both be used to detect in children's hospital-acquired pneumonia.

Mojtahedi S, Rahbarimanesh A, Noorbakhsh S, Shokri H, Jamali-Moghadam-Siyahkali S, Izadi A Eur J Transl Myol. 2019; 29(2):8120.

PMID: 31354920 PMC: 6615363. DOI: 10.4081/ejtm.2019.8120.


References
1.
van der Zee A, Peeters M, de Jong C, Verbakel H, Crielaard J, Claas E . Qiagen DNA extraction kits for sample preparation for legionella PCR are not suitable for diagnostic purposes. J Clin Microbiol. 2002; 40(3):1126. PMC: 120297. DOI: 10.1128/JCM.40.3.1128.2002. View

2.
Murdoch D, Walford E, Jennings L, Light G, Schousboe M, Chereshsky A . Use of the polymerase chain reaction to detect Legionella DNA in urine and serum samples from patients with pneumonia. Clin Infect Dis. 1996; 23(3):475-80. DOI: 10.1093/clinids/23.3.475. View

3.
Corless C, Guiver M, Borrow R, Edwards-Jones V, Kaczmarski E, Fox A . Contamination and sensitivity issues with a real-time universal 16S rRNA PCR. J Clin Microbiol. 2000; 38(5):1747-52. PMC: 86577. DOI: 10.1128/JCM.38.5.1747-1752.2000. View

4.
Wellinghausen N, Frost C, Marre R . Detection of legionellae in hospital water samples by quantitative real-time LightCycler PCR. Appl Environ Microbiol. 2001; 67(9):3985-93. PMC: 93119. DOI: 10.1128/AEM.67.9.3985-3993.2001. View

5.
Ballard A, Fry N, Chan L, Surman S, Lee J, Harrison T . Detection of Legionella pneumophila using a real-time PCR hybridization assay. J Clin Microbiol. 2000; 38(11):4215-8. PMC: 87566. DOI: 10.1128/JCM.38.11.4215-4218.2000. View