» Articles » PMID: 12943876

Second-generation Tissue Doppler with Angle-corrected Color-coded Wall Displacement for Quantitative Assessment of Regional Left Ventricular Function

Overview
Journal Am J Cardiol
Date 2003 Aug 29
PMID 12943876
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

To test the hypothesis that a new tissue Doppler (TD) approach using angle-correction and transformation of velocity data to color-coded displacement data may objectively quantify regional left ventricular function, in vitro experiments were first performed with an oscillating echo target precisely controlled by a microstepping motor. Displacement varied from 1 to 15 mm (60 to 130 cycles/min) at angles of 0 degrees and 45 degrees to the echo transducer. Custom software transformed TD data to displacement data. Sixty-five subjects were then studied: 35 with wall motion abnormalities and 30 normal controls. Results were compared with independent visual assessment and caliper measurements of endocardial excursion from gray-scale images. In vitro displacement imaging strongly correlated with true displacement (r = 0.99, p <0.0001). In humans, peak transmural displacement discriminated normal results (6.3 +/- 3.2 mm) from hypokinesia (2.7 +/- 1.8 mm, p <0.05), akinesia (0.4 +/- 1.2 mm, p <0.05) from hypokinesia, and dyskinesia (-1.9 +/- 1.2 mm, p <0.05) from akinesia. Normal subendocardial displacement was 5.9 +/- 2.9 versus 4.0 +/- 3.9 mm in the epicardial layer (p <0.01). This displacement gradient was absent in abnormal segments. Displacement data correlated with endocardial excursion by calipers (parasternal views: r = 0.86, all views: r = 0.79, both p <0.0001). Overall accuracy of displacement imaging was 82% (kappa = 0.71) versus 66% (kappa = 0.43) for visual assessment with caliper data as the standard of reference. Angle-corrected displacement imaging was superior to routine visual assessment and is a promising new method to quantify regional left ventricular function.

Citing Articles

Differential Effects of Ventricular Pacing Sites of Contraction Synchrony and Global Cardiac Performance.

Alhammouri M, Kim H, Mokhtar Y, Cannesson M, Tanabe M, Gorcsan 3rd J Crit Care Shock. 2011; 12(2).

PMID: 21949483 PMC: 3178394.


Echocardiographic speckle tracking radial strain imaging to assess ventricular dyssynchrony in a pacing model of resynchronization therapy.

Tanabe M, Lamia B, Tanaka H, Schwartzman D, Pinsky M, Gorcsan 3rd J J Am Soc Echocardiogr. 2008; 21(12):1382-8.

PMID: 19041581 PMC: 3001299. DOI: 10.1016/j.echo.2008.09.012.