Abstract

Inhalable and total dust sampling devices were compared for evaluating airborne dust in swine confinement buildings. Measurements from three swine facilities (n = 77 paired means) were obtained by area sampling using the IOM (Institute of Occupational Medicine, Edinburgh, U.K.) inhalable dust sampler and a 37-mm closed-face total (TCF) dust sampler. The overall geometric mean IOM concentration (1.18 mg/m(3), geometric standard deviation [GSD] = 2.00) was significantly greater (P < 0.05) than the overall geometric mean TCF concentration (1.08 mg/m(3), GSD = 1.98). Regression analysis with IOM and TCF values as independent and dependent variables, respectively, yielded a factor of 0.86 (+/-0.04 95% confidence interval), which can be used to estimate TCF values from the IOM measurements. Additional paired sampling data were obtained to compare the following pairs of dust samplers: (1) IOM sampler and conical inhalable sampler (CIS) (n = 20 paired means), (2) IOM and open-face total (TOF) dust samplers (n = 14), (3) CIS and TCF samplers (n = 19), and (4) TCF and TOF samplers (n = 8). Paired t-tests showed significantly (P < 0.05) higher IOM concentrations than the CIS sampler; no significant difference (P > 0.05) was found for the other three pairs compared. It may be necessary to establish work-specific conversion coefficients to obtain a reasonable estimate of worker exposure to total dust from measurements using other types of dust sampling devices.

Citing Articles

Use of prototype side stream filtration system to control dust levels in a commercial swine farrowing building.

Sousan S, Anthony T, Altmaier R, Gibbs J, Nonnenmann M J Occup Environ Hyg. 2023; 20(12):633-645.

PMID: 37582250 PMC: 10918672. DOI: 10.1080/15459624.2023.2247457.


A field evaluation of a single sampler for respirable and inhalable indium and dust measurements at an indium-tin oxide manufacturing facility.

Blackley B, Gibbs J, Cummings K, Stefaniak A, Park J, Stanton M J Occup Environ Hyg. 2018; 16(1):66-77.

PMID: 30325716 PMC: 6419101. DOI: 10.1080/15459624.2018.1536826.


Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room.

Anthony T, Altmaier R, Jones S, Gassman R, Park J, Peters T J Occup Environ Hyg. 2015; 12(9):635-46.

PMID: 25950713 PMC: 4756717. DOI: 10.1080/15459624.2015.1029616.


Airborne cow allergen, ammonia and particulate matter at homes vary with distance to industrial scale dairy operations: an exposure assessment.

Williams D, Breysse P, McCormack M, Diette G, McKenzie S, Geyh A Environ Health. 2011; 10:72.

PMID: 21838896 PMC: 3184623. DOI: 10.1186/1476-069X-10-72.


A task-specific assessment of Swine worker exposure to airborne dust.

OShaughnessy P, Donham K, Peters T, Taylor C, Altmaier R, Kelly K J Occup Environ Hyg. 2009; 7(1):7-13.

PMID: 19904655 PMC: 10466474. DOI: 10.1080/15459620903327970.