Journal Med Phys
Specialty Biophysics
Date 2003 Aug 9
PMID 12906201
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

An algorithm for the daily localization of the prostate using implanted markers and a standard video-based electronic portal imaging device (V-EPID) has been tested. Prior to planning, three gold markers were implanted in the prostate of seven patients. The clinical images were acquired with a BeamViewPlus 2.1 V-EPID for each field during the normal course radiotherapy treatment and are used off-line to determine the ability of the automatic marker detection algorithm to adequately and consistently detect the markers. Clinical images were obtained with various dose levels from ranging 2.5 to 75 MU. The algorithm is based on marker attenuation characterization in the portal image and spatial distribution. A total of 1182 clinical images were taken. The results show an average efficiency of 93% for the markers detected individually and 85% for the group of markers. This algorithm accomplishes the detection and validation in 0.20-0.40 s. When the center of mass of the group of implanted markers is used, then all displacements can be corrected to within 1.0 mm in 84% of the cases and within 1.5 mm in 97% of cases. The standard video-based EPID tested provides excellent marker detection capability even with low dose levels. The V-EPID can be used successfully with radiopaque markers and the automatic detection algorithm to track and correct the daily setup deviations due to organ motions.

Citing Articles

Computed tomography based evaluation of prostatic fiducial marker migration between the periods of insertion and simulation.

Arpaci T, Ugurluer G, Ispir E, Eken A, Akbas T, Serin M Turk J Urol. 2017; 43(4):451-455.

PMID: 29201507 PMC: 5687207. DOI: 10.5152/tud.2017.29726.


Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.

Campbell W, Miften M, Jones B Med Phys. 2016; 44(2):364-374.

PMID: 28035655 PMC: 5538726. DOI: 10.1002/mp.12073.


A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections.

Poulsen P, Fledelius W, Keall P, Weiss E, Lu J, Brackbill E Med Phys. 2011; 38(4):2151-6.

PMID: 21626948 PMC: 3078162. DOI: 10.1118/1.3555295.


Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: a feasibility and accuracy study.

Adamson J, Wu Q Med Phys. 2008; 35(5):1793-806.

PMID: 18561654 PMC: 2507873. DOI: 10.1118/1.2899998.