The Effects of Hydroxyapatite Coating and Bone Allograft on Fixation of Loaded Experimental Primary and Revision Implants

Overview
Specialty Orthopedics
Date 2003 Aug 6
PMID 12899541
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

We used our established experimental model of revision joint replacement to examine the roles of hydroxyapatite coating and bone graft in improving the fixation of revision implants. The revision protocol uses the Søballe micromotion device in a preliminary 8-week period of implant instability for the presence of particulate polyethylene. During this procedure, a sclerotic endosteal bone rim forms, and a dense fibrous membrane is engendered, having macrophages with ingested polyethylene and high levels of inflammatory cytokines. At the time of revision after 8 weeks, the cavity is revised with either a titanium alloy (Ti) or a hydroxyapatite (HA) 6.0 mm plasma-sprayed implant, in the presence or absence of allograft packed into the initial 0.75 mm peri-implant gap. The contralateral limb is subjected to primary surgery with the same implant configuration, and serves as control. 8 implants were included in each of the 8 treatment groups (total 64 implants in 32 dogs). The observation period was 4 weeks after revision. Outcome measures are based on histomorphometry and mechanical pushout properties. The revision setting was always inferior to its primary counterpart. Bone graft improved the revision fixation in all treatment groups, as also did the HA coating. The sole exception was revision-grafted HA implants, which reached the same fixation as primary Ti and HA grafted implants. The revision, which was less active in general, seems to need the dual stimulation of bone graft and HA implant surface, to obtain the same level of fixation associated with primary implants. Our findings suggest that the combination of HA implant and bone graft may be of benefit in the clinical revision implant setting.

Citing Articles

Potential bioactive coating system for high-performance absorbable magnesium bone implants.

Nazira Sarian M, Iqbal N, Sotoudehbagha P, Razavi M, Ahmed Q, Sukotjo C Bioact Mater. 2022; 12:42-63.

PMID: 35087962 PMC: 8777287. DOI: 10.1016/j.bioactmat.2021.10.034.


The limit of tolerable micromotion for implant osseointegration: a systematic review.

Kohli N, Stoddart J, Van Arkel R Sci Rep. 2021; 11(1):10797.

PMID: 34031476 PMC: 8144379. DOI: 10.1038/s41598-021-90142-5.


Hydroxyapatite nanoparticles derived from mussel shells for cytotoxicity test and cell viability.

El-Bassyouni G, Eldera S, Kenawy S, Hamzawy E Heliyon. 2020; 6(6):e04085.

PMID: 32529074 PMC: 7281827. DOI: 10.1016/j.heliyon.2020.e04085.


Arthrotomy-based preclinical models of particle-induced osteolysis: A systematic review.

Moran M, Wilson B, Ross R, Virdi A, Sumner D J Orthop Res. 2017; 35(12):2595-2605.

PMID: 28548682 PMC: 5702596. DOI: 10.1002/jor.23619.


Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?.

Elmengaard B, Baas J, Jakobsen T, Kold S, Jensen T, Bechtold J Clin Orthop Relat Res. 2016; 475(2):442-451.

PMID: 27554268 PMC: 5213936. DOI: 10.1007/s11999-016-5022-x.


References
1.
Stevenson S, Li X, Martin B . The fate of cancellous and cortical bone after transplantation of fresh and frozen tissue-antigen-matched and mismatched osteochondral allografts in dogs. J Bone Joint Surg Am. 1991; 73(8):1143-56. View

2.
Karrholm J, Malchau H, Snorrason F, Herberts P . Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am. 1994; 76(11):1692-705. DOI: 10.2106/00004623-199411000-00013. View

3.
van Blitterswijk C, Grote J, Kuypers W, DAEMS W . Bioreactions at the tissue/hydroxyapatite interface. Biomaterials. 1985; 6(4):243-51. DOI: 10.1016/0142-9612(85)90020-1. View

4.
Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J . Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res. 1997; (344):94-110. View

5.
Nelissen R, Valstar E, Rozing P . The effect of hydroxyapatite on the micromotion of total knee prostheses. A prospective, randomized, double-blind study. J Bone Joint Surg Am. 1998; 80(11):1665-72. DOI: 10.2106/00004623-199811000-00014. View