» Articles » PMID: 12851764

Comparative Effects of Helium-oxygen and External Positive End-expiratory Pressure on Respiratory Mechanics, Gas Exchange, and Ventilation-perfusion Relationships in Mechanically Ventilated Patients with Chronic Obstructive Pulmonary Disease

Overview
Specialty Critical Care
Date 2003 Jul 10
PMID 12851764
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To compare the effects of He/O(2) and external PEEP (PEEPe) on intrinsic PEEP (PEEPi), respiratory mechanics, gas exchange, and ventilation/perfusion (V(A)/Q) in mechanically ventilated COPD patients.

Design And Setting: Prospective, interventional study in the intensive care unit of a university hospital.

Interventions: Ten intubated, sedated, paralyzed, mechanically ventilated COPD patients studied in the following conditions: (a) baseline settings made by clinician in charge, air/O(2), ZEEP; (b) He/O(2), ZEEP; (c) air/O(2), ZEEP; (d) air/O(2), PEEPe 80% of PEEPi. Measurements at each condition included V(A)/Q by the multiple inert gas elimination technique (MIGET).

Results: PEEPi and trapped gas volume were comparably reduced by He/O(2) (4.2+/-4 vs. 7.7+/-4 cmH(2)O and 98+/-82 vs. 217+/-124 ml, respectively) and PEEPe (4.4+/-1.3 vs. 7.8+/-3.6 cmH(2)O and 120+/-107 vs. 216+/-115 ml, respectively). He/O(2) reduced inspiratory and expiratory respiratory system resistance (15.5+/-4.4 vs. 20.7+/-6.9 and 19+/-9 vs. 28.8+/-15 cmH(2)O l(-1)s(-1), respectively) and plateau pressure (13+/-4 vs. 17+/-6 cmH(2)O). PEEPe increased airway pressures, including total PEEP, and elastance. PaO(2)/FIO(2) was slightly reduced by He/O(2) (225+/-83 vs. 245+/-82) without significant V(A)/Q change.

Conclusions: He/O(2) and PEEPe comparably reduced PEEPi and trapped gas volume. However, He/O(2) decreased airway resistance and intrathoracic pressures, at a small cost in arterial oxygenation. He/O(2) could offer an attractive option in COPD patients with PEEPi/dynamic hyperinflation.

Citing Articles

Mechanical ventilation in patients with chronic obstructive pulmonary disease and bronchial asthma.

Ahmed S, Athar M Indian J Anaesth. 2015; 59(9):589-98.

PMID: 26556918 PMC: 4613406. DOI: 10.4103/0019-5049.165856.


Can computer simulators accurately represent the pathophysiology of individual COPD patients?.

Wang W, Das A, Ali T, Cole O, Chikhani M, Haque M Intensive Care Med Exp. 2015; 2(1):23.

PMID: 26266920 PMC: 4513041. DOI: 10.1186/s40635-014-0023-0.


The porcine lung as a potential model for cystic fibrosis.

Rogers C, Abraham W, Brogden K, Engelhardt J, Fisher J, McCray Jr P Am J Physiol Lung Cell Mol Physiol. 2008; 295(2):L240-63.

PMID: 18487356 PMC: 2519845. DOI: 10.1152/ajplung.90203.2008.


Helium-oxygen decreases inspiratory effort and work of breathing during pressure support in intubated patients with chronic obstructive pulmonary disease.

Tassaux D, Gainnier M, Battisti A, Jolliet P Intensive Care Med. 2005; 31(11):1501-7.

PMID: 16172846 DOI: 10.1007/s00134-005-2796-9.


Year in review in Intensive Care Medicine-2003. Part 1: Respiratory failure, infection and sepsis.

Abraham E, Andrews P, Antonelli M, Brochard L, Brun-Buisson C, Dobb G Intensive Care Med. 2004; 30(6):1017-31.

PMID: 15170528 DOI: 10.1007/s00134-004-2321-6.

References
1.
Pauwels R, Buist A, Calverley P, Jenkins C, Hurd S . Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. Am J Respir Crit Care Med. 2001; 163(5):1256-76. DOI: 10.1164/ajrccm.163.5.2101039. View

2.
Jaber S, Fodil R, Carlucci A, Boussarsar M, Pigeot J, Lemaire F . Noninvasive ventilation with helium-oxygen in acute exacerbations of chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 2000; 161(4 Pt 1):1191-200. DOI: 10.1164/ajrccm.161.4.9904065. View

3.
Nava S, Bruschi C, Rubini F, Palo A, Iotti G, Braschi A . Respiratory response and inspiratory effort during pressure support ventilation in COPD patients. Intensive Care Med. 1995; 21(11):871-9. DOI: 10.1007/BF01712327. View

4.
Tassaux D, Jolliet P, Thouret J, Roeseler J, Dorne R, Chevrolet J . Calibration of seven ICU ventilators for mechanical ventilation with helium-oxygen mixtures. Am J Respir Crit Care Med. 1999; 160(1):22-32. DOI: 10.1164/ajrccm.160.1.9807127. View

5.
Tuxen D, Lane S . The effects of ventilatory pattern on hyperinflation, airway pressures, and circulation in mechanical ventilation of patients with severe air-flow obstruction. Am Rev Respir Dis. 1987; 136(4):872-9. DOI: 10.1164/ajrccm/136.4.872. View