The PEP Respiratory Monitor: a Validation Study

Overview
Journal Emerg Med J
Specialty Emergency Medicine
Date 2003 Jul 2
PMID 12835340
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The search for a reliable and accurate respiratory rate monitor for use in non-intubated patients has proved to be a long and fruitless one. A new device fulfilling the criteria for such a monitor has recently been described. The pyroelectric polymer (PEP) device is safe, non-invasive, and cheap. In this study the PEP device, transthoracic impedance, and standard observer counting were all compared with the existing gold standard of capnography in 12 healthy adult volunteers. Using a standard statistical technique it was shown that the PEP device performed as well as a capnograph and was more accurate than the other currently available methods of monitoring respiratory rate.

Citing Articles

Feasibility study of the use of a wearable vital sign patch in an intensive care unit setting.

Stevens G, Larmuseau M, Van Damme A, Vanoverschelde H, Heerman J, Verdonck P J Clin Monit Comput. 2024; 39(1):245-256.

PMID: 39158782 DOI: 10.1007/s10877-024-01207-5.


Wearable Vital Signs Monitoring for Patients With Asthma: A Review.

Taylor L, Ding X, Clifton D, Lu H IEEE Sens J. 2023; 23(3):1734-1751.

PMID: 37655115 PMC: 7615004. DOI: 10.1109/JSEN.2022.3224411.


Measurement of Vital Signs Using Lifelight Remote Photoplethysmography: Results of the VISION-D and VISION-V Observational Studies.

Heiden E, Jones T, Brogaard Maczka A, Kapoor M, Chauhan M, Wiffen L JMIR Form Res. 2022; 6(11):e36340.

PMID: 36374541 PMC: 9706384. DOI: 10.2196/36340.


Contact and Remote Breathing Rate Monitoring Techniques: A Review.

Ali M, Elsayed A, Mendez A, Savaria Y, Sawan M IEEE Sens J. 2022; 21(13):14569-14586.

PMID: 35789086 PMC: 8769001. DOI: 10.1109/JSEN.2021.3072607.


A Study on the Effect of Contact Pressure during Physical Activity on Photoplethysmographic Heart Rate Measurements.

Scardulla F, DAcquisto L, Colombarini R, Hu S, Pasta S, Bellavia D Sensors (Basel). 2020; 20(18).

PMID: 32899540 PMC: 7570982. DOI: 10.3390/s20185052.


References
1.
Plewa M, Sikora S, Engoren M, Tome D, Thomas J, Deuster A . Evaluation of capnography in nonintubated emergency department patients with respiratory distress. Acad Emerg Med. 1995; 2(10):901-8. DOI: 10.1111/j.1553-2712.1995.tb03106.x. View

2.
Isaacs D . Bronchiolitis. BMJ. 1995; 310(6971):4-5. PMC: 2548431. DOI: 10.1136/bmj.310.6971.4. View

3.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

4.
Kulkarni V, Cyna A, Hutchison J, Tunstall M, MALLARD J . AURA: a new respiratory monitor. Biomed Sci Instrum. 1990; 26:111-20. View

5.
Gravelyn T, Weg J . Respiratory rate as an indicator of acute respiratory dysfunction. JAMA. 1980; 244(10):1123-5. View