» Articles » PMID: 12809155

Visual Acuity and Its Measurement

Overview
Specialty Ophthalmology
Date 2003 Jun 18
PMID 12809155
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

Despite its critical importance to our daily life, the most common measurement of visual function, visual acuity, is a relatively crude and narrow one testing only a small portion of the broad range of visual functions. Visual acuity is the measurement of the ability to discriminate two stimuli separated in space at high contrast relative to the background. Clinically, this is measured by asking the subject to discriminate letters of known visual angle. The visual acuity is represented as the reciprocal of the minimal angle of resolution (the smallest letters resolved) at a given distance and at high contrast. Other measurements of visual acuity also exist, including Vernier acuity. Newer charts, such as the ETDRS chart, use letters of equal recognition difficulty and use the log of the minimal angle of resolution; these charts have significant advantages over the old Snellen-type charts. This article reviews visual measurements in children and in patients with low vision, and it reviews factors affecting visual acuity, such as pupil size, refractive error, media opacities, and pharmacologic agents.

Citing Articles

Assessment of Emergency Department Intraocular Pressure and Visual Acuity Assessment as a Screening Exam.

Bojikian K, Leveque T, McEvoy A, Hopkin B, Popovici N, Hopkin H Clin Ophthalmol. 2025; 19:683-690.

PMID: 40026816 PMC: 11871949. DOI: 10.2147/OPTH.S511327.


Avatar-based versus conventional patient monitoring with distant vision: a computer-based simulation study.

Milovanovic P, Braun J, Hunn C, Lunkiewicz J, Tscholl D, Gasciauskaite G J Clin Monit Comput. 2024; .

PMID: 39546214 DOI: 10.1007/s10877-024-01239-x.


The Impact of Socioeconomic Status on Visual Acuity Changes in Schoolchildren: A One-Year Follow-Up.

Galdon A, Vila-Vidal N, Gharbi M, Vinuela-Navarro V, Perez-Corral J, Tomas N Children (Basel). 2024; 11(10).

PMID: 39457191 PMC: 11506476. DOI: 10.3390/children11101226.


Web-based vs. conventional: a comprehensive analysis of visual acuity assessment using the PocDoc tool in a tertiary eye care centre.

Boon J, Goh J, Rojas-Carabali W, Puah M, Lee B, Rajagopalan R Eye (Lond). 2024; 38(18):3554-3561.

PMID: 39420108 PMC: 11621426. DOI: 10.1038/s41433-024-03362-0.


Comparison between Different Visual Acuity Tests and Validation of a Digital Device.

Montori B, Perez Roche T, Vilella M, Lopez E, Alejandre A, Pan X Vision (Basel). 2024; 8(3).

PMID: 39330761 PMC: 11437472. DOI: 10.3390/vision8030057.