» Articles » PMID: 12781279

Early Rotational Stability of the Longer Staar Toric Intraocular Lens: Fifty Consecutive Cases

Overview
Specialty Ophthalmology
Date 2003 Jun 5
PMID 12781279
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine whether rotational stability is improved with the longer Staar toric intraocular lens (IOL).

Setting: A private practice, Los Altos, California, USA.

Methods: Staar Surgical manufactures toric plate-haptic IOLs under +24.0 diopters (D) in 2 lengths. Fifty consecutive eyes requiring toric IOL spherical powers less than +24.0 D received the longer toric IOL (TL; 11.2 mm) using a specific surgical protocol. The IOL axis was recorded at 1 day, 1 week, and a final follow-up visit. Five additional eyes requiring powers greater than +24.0 D received the shorter toric IOL (TF; 10.8 mm), which is the only available length in these powers. Results were compared with those in an initial consecutive series of 6 eyes having implantation of the TF IOL with a power less than +24.0 D before the TL model became available.

Results: Rotational stability of all 50 TL IOLs and the 5 TF IOLs of higher dioptric powers was excellent. One IOL rotated as much as 20 degrees off axis. The repositioning rate was zero in both groups. In the initial 6 eyes receiving the shorter toric IOL in powers below +24.0 D, the repositioning rate was 50%.

Conclusions: The longer toric IOL had excellent early rotational stability. Rotational and repositioning rates with the TL IOL were superior to those in a previous series of the TF IOL. Adequate overall length is a critical factor in the rotational stability of plate-haptic toric IOLs, and the longer IOL should be used when available.

Citing Articles

Clinical Results of a Monofocal Aspheric Bitoric Intraocular Lens with Plate Haptics in Hyperopic Eyes.

Tana-Rivero P, Munoz-Tomas J, Orts-Vila P, Artiaga-Elordi E, Pastor-Pascual F, Marin-Sanchez J Clin Ophthalmol. 2024; 18:1933-1944.

PMID: 38983598 PMC: 11231029. DOI: 10.2147/OPTH.S467523.


Systematic bibliometric analysis of research hotspots and trends on the application of premium IOLs in the past 2 decades.

Li L, Yuan L, Mao D, Hua X, Yuan X Int J Ophthalmol. 2024; 17(4):736-747.

PMID: 38638264 PMC: 10988063. DOI: 10.18240/ijo.2024.04.19.


Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies.

Lin X, Ma D, Yang J Front Med (Lausanne). 2024; 11:1349496.

PMID: 38414624 PMC: 10896894. DOI: 10.3389/fmed.2024.1349496.


Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial.

Sun J, Bai H, Cui W, Wu X Graefes Arch Clin Exp Ophthalmol. 2023; 262(3):847-855.

PMID: 37672101 DOI: 10.1007/s00417-023-06232-9.


Efficacy of a One-Piece Aberration Neutral Hydrophobic Acrylic Toric Intraocular Lens.

Buckhurst P, Lau G, Williams J, Packer M Clin Ophthalmol. 2022; 16:3763-3774.