» Articles » PMID: 12671498

Tibial Component Fixation with Cement: Full- Versus Surface-cementation Techniques

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 2003 Apr 3
PMID 12671498
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Despite excellent outcomes with cemented tibial components in total knee arthroplasty, it still is debated whether the tibial stem should be cemented and what the optimal tibial stem design should be. Proponents of full cementation of the tibial stem and component state that better short-term and long-term component fixation is achieved when full cementation is used. Advocates for surface cementation contend that sufficient implant stability is achieved without the increased bone loss that occurs at revision and the stress shielding thought to be linked with cemented stems. This biomechanical cadaver study compared initial fixation and cement penetration depth in fully cemented versus surface cemented tibial trays with two different stem geometries (cruciate and I-beam) and compared two stem designs (cruciate and I-beam) fixed with surface cementation. Under an eccentric load, simulating three times body weight for 6000 cycles, there seems to be no difference in the micromotion of either tibial component implanted with surface or full cementation. Additionally, no difference in the average depth of cement penetration was detected between fixation techniques or stem types. The initial fixation stability of the surface cement technique seems correlated to the depth of cement penetration into proximal tibial surface. The current data support other studies which indicate that stability of surface-cemented tibial components may be related to the depth of cement penetration.

Citing Articles

Does Tourniquet Use Impact Early Patient Outcomes in Total Knee Arthroplasty?.

Elbeshbeshy M, Azhar M, Luqman M, Sabahuddin A, Bashir O, Saber A Cureus. 2024; 16(11):e73379.

PMID: 39659304 PMC: 11630058. DOI: 10.7759/cureus.73379.


Pulsed lavage is associated with better quality of bone-cement-implant interface in knee arthroplasties (TKA/UKA) compared to syringe lavage in vitro; however, clinical data are missing: A systematic review.

Di Maria F, Das S, Abermann E, Hoser C, Fink C J Exp Orthop. 2024; 11(3):e12027.

PMID: 38774578 PMC: 11106550. DOI: 10.1002/jeo2.12027.


Consequences of using poly-ether-ether-ketone versus traditional implant on tibial cement penetration and short-term clinical outcomes during total knee arthroplasty: a randomized controlled trial.

Zhao G, Yao S, Sun X, Ma J, Wang J J Orthop Surg Res. 2023; 18(1):589.

PMID: 37559133 PMC: 10410788. DOI: 10.1186/s13018-023-04064-1.


The Effect of Working Time and Application Technique on Cement Penetration into a Tibial Model.

Schmicker T, Goel A, Davis S, Sina Adil S, Oliashirazi A, Bullock M Arthroplast Today. 2022; 16:197-202.

PMID: 35844266 PMC: 9284312. DOI: 10.1016/j.artd.2022.04.011.


The use of tantalum cones and diaphyseal-engaging stems in tibial component revision: a consecutive series.

Spinello P, Thiele R, Zepeda K, Giori N, Indelli P Knee Surg Relat Res. 2022; 34(1):12.

PMID: 35272710 PMC: 8908299. DOI: 10.1186/s43019-022-00141-7.