Improved Detection of Hepatic Metastases with Pulse-inversion US During the Liver-specific Phase of SHU 508A: Multicenter Study

Abstract

Purpose: To compare conventional B-mode ultrasonography (US) alone with the combination of conventional B-mode US and contrast material-enhanced (SHU 508A) late-phase pulse-inversion US for the detection of hepatic metastases by using dual-phase spiral computed tomography (CT) as the standard of reference.

Materials And Methods: One hundred twenty-three patients underwent conventional US, US in the liver-specific phase of SHU 508A, and single-section spiral CT. US and CT images were assessed by blinded readers. Differences in sensitivity, specificity, and the number and smallest size of metastases at conventional and contrast-enhanced US were compared by using CT as the standard of reference. Lesion conspicuity was assessed objectively (quantitatively) and subjectively by one reader before and after contrast material administration.

Results: In 45 of 80 (56%) patients with metastases, more metastases were seen at contrast-enhanced US than at conventional US. In three of these patients, conventional US images appeared normal. The addition of contrast-enhanced US improved sensitivity for the detection of individual metastases from 71% to 87% (P <.001). On a patient basis, sensitivity improved from 94% to 98% (P =.44), and specificity improved from 60% to 88% (P <.01). Contrast enhancement improved the subjective conspicuity of metastases in 66 of 75 (88%) patients and the objective contrast by a mean of 10.8 dB (P <.001). Contrast-enhanced US showed more metastases than did CT in seven patients, and CT showed more than did contrast-enhanced US in one of 22 patients in whom an independent reference (magnetic resonance imaging, intraoperative US, or pathologic findings) was available.

Conclusion: Contrast-enhanced US improved sensitivity and specificity in the detection of hepatic metastases.

Citing Articles

Contrast enhanced ultrasound guided biopsies of liver lesions not visualized on standard B-mode ultrasound-preliminary experience.

Partovi S, Lu Z, Kessner R, Yu A, Ahmed Y, Patel I J Gastrointest Oncol. 2018; 8(6):1056-1064.

PMID: 29299367 PMC: 5750174. DOI: 10.21037/jgo.2017.08.17.


Characterization of Focal Liver Lesions Indistinctive on B Mode Ultrasound: Benefits of Contrast-Enhanced Ultrasound.

Dong Y, Mao F, Cao J, Fan P, Wang W Biomed Res Int. 2017; 2017:8970156.

PMID: 28497069 PMC: 5405373. DOI: 10.1155/2017/8970156.


Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers.

Bo X, Xu H, Wang D, Guo L, Sun L, Li X Br J Radiol. 2016; 89(1067):20160379.

PMID: 27626506 PMC: 5124839. DOI: 10.1259/bjr.20160379.


Morphologic and Functional Imaging of Non-Colorectal Liver Metastases.

Heusch P, Antoch G Viszeralmedizin. 2016; 31(6):387-92.

PMID: 26889141 PMC: 4748792. DOI: 10.1159/000441857.


Intraoperative Contrast-Enhanced Ultrasound in Colorectal Liver Metastasis Surgery Improves the Identification and Characterization of Nodules.

Hoareau J, Venara A, Lebigot J, Hamel J, Lermite E, Caroli-Bosc F World J Surg. 2015; 40(1):190-7.

PMID: 26470698 DOI: 10.1007/s00268-015-3269-0.