» Articles » PMID: 12638057

Simultaneous Determination of 2-nitrophenol and 4-nitrophenol Based on the Multi-wall Carbon Nanotubes Nafion-modified Electrode

Overview
Specialty Chemistry
Date 2003 Mar 15
PMID 12638057
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

In this work, multi-wall carbon nanotubes (MWNT) were conveniently dispersed into Nafion-ethanol solution, and the MWNT-Nafion-modified glassy carbon electrode (GCE) was described for the simultaneous determination of 2-nitrophenol and 4-nitrophenol. At pH 4.0 phosphate buffer, the reduction peak currents of 2-nitrophenol (at -0.8 V) and 4-nitrophenol (at -1.0 V) increase significantly at the MWNT-Nafion-modified GCE, in comparison with that at the Nafion-modified GCE and the bare GCE. The experimental parameters, such as solution pH of phosphate buffer, accumulation potential and time, and the amounts of MWNT-Nafion onto the GCE surface, were optimized. The reduction peak currents are linear with the concentration of 2-nitrophenol from 5 x 10(-8) to 1 x 10(-5) mol L(-1) and with that of 4-nitrophenol from 1 x 10(-7) to 1 x 10(-5) mol L(-1). The detection limits after 3-min accumulation are 1 x 10(-8) mol L(-1) for 2-nitrophenol and for 4 x 10(-8) mol L(-1) for 4-nitrophenol. This modified electrode was applied to direct determination of 2-nitrophenol and 4-nitrophenol in lake water samples.

Citing Articles

Electrochemical Detection of 4-Nitrophenol Using a Novel SrTiO/Ag/rGO Composite.

M Visagamani A, Harb M, Kaviyarasu K, Muthukrishnaraj A, Ayyar M, Alzahrani K ACS Omega. 2023; 8(45):42479-42491.

PMID: 38024753 PMC: 10652362. DOI: 10.1021/acsomega.3c05111.


Evaluation of the electrochemical response of using screen-printed carbon electrodes (SPCE) modified with oxidized multi-walled carbon nanotubes dispersed in water - Nafion®.

Acevedo-Restrepo I, Blandon-Naranjo L, Vazquez M, Restrepo-Sanchez N Curr Res Food Sci. 2022; 6:100401.

PMID: 36479227 PMC: 9720410. DOI: 10.1016/j.crfs.2022.11.020.


Novel construction of carbon nanofiber/CuCrO composite for selective determination of 4-nitrophenol in environmental samples and for supercapacitor application.

Sakthinathan S, Rajakumaran R, Keyan A, Yu C, Wu C, Vinothini S RSC Adv. 2022; 11(26):15856-15870.

PMID: 35481186 PMC: 9030931. DOI: 10.1039/d1ra02783b.


Performance of graphene-zinc oxide nanocomposite coated-glassy carbon electrode in the sensitive determination of para-nitrophenol.

Dar R, Naikoo G, Srivastava A, Ul Hassan I, Karna S, Giri L Sci Rep. 2022; 12(1):117.

PMID: 34996919 PMC: 8741969. DOI: 10.1038/s41598-021-03495-2.


Facile and Ultrasensitive Determination of 4-Nitrophenol Based on Acetylene Black Paste and Graphene Hybrid Electrode.

He Q, Tian Y, Wu Y, Liu J, Li G, Deng P Nanomaterials (Basel). 2019; 9(3).

PMID: 30871263 PMC: 6473960. DOI: 10.3390/nano9030429.